EN Snare® 00884450452479Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00884450452479), received between Nov 18, 2020 and Jul 8, 2025 — classified as 4 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Fracture” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture5
- Material Separation5
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Foreign Body In Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryJul 8, 2025Fracture; Fracture
THE ACCOUNT ALLEGES THAT THE FLOWER PORTION OF THE ENSNARE DETACHED FROM WIRE PORTION. FLOWER PORTION WAS LEFT IN THE PATIENT WHILE THE WIRE WAS REMOVED.
Patient problems: Foreign Body In Patient
MAUDE report 22440621 ↗InjurySep 8, 2022Fracture; Material Separation; Fracture; Material Separation
THE ACCOUNT ALLEGES THAT DURING A URETERIC STENT REMOVAL PROCEDURE, THE DISTAL PORTION OF A VASCULAR SNARE DEVICE DETACHED WITHIN THE PATIENT DURING THE REMOVAL PROCESSES. THE PHYSICIAN SUCCESSFULLY EXTERNALIZED THE FOREIGN BODY WITH ANOTHER VASCULAR SNARE DEVICE LIBERATING THE VESSEL. THE PROCEDURE WAS SUCCESSFULLY COMPLETED FOR THIS PATIENT. NO ADDITIONAL CONSEQUENCES TO REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15380222 ↗InjuryFeb 23, 2022Fracture; Material Separation; Fracture; Material Separation
THE ACCOUNT ALLEGES THAT DURING AN INFERIOR VENA CAVA FILTER REMOVAL PROCEDURE ON A REFERRAL PATIENT, THE TIP OF A VASCULAR SNARE DEVICE DETACHED WITHIN THE PATIENTS IVC. A SECOND VASCULAR SNARE DEVICE WAS PREPPED AND DEPLOYED IN ATTEMPTS TO REMOVE THE PRIMARY FOREIGN BODY FROM THE PATIENT WHEN THE TIP OF THE SECOND SNARE DEVICE ALSO DETACHED. THE PHYSICIAN STATES THAT USUAL RESISTANCE WAS EXPERIENCED DURING THE REMOVAL PROCEDURE EVEN THOUGH THE FILTER WAS EMBEDDED WITHIN THE WALL OF THE IVC. ORIGINAL IMPLANT DATE IN UNKNOWN. NO ADDITIONAL CONSEQUENCES TO REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13588639 ↗InjuryFeb 23, 2022Fracture; Material Separation; Fracture; Material Separation
THE ACCOUNT ALLEGES THAT DURING AN INFERIOR VENA CAVA FILTER REMOVAL PROCEDURE ON A REFERRAL PATIENT, THE TIP OF A VASCULAR SNARE DEVICE DETACHED WITHIN THE PATIENTS IVC. A SECOND VASCULAR SNARE DEVICE WAS PREPPED AND DEPLOYED IN ATTEMPTS TO REMOVE THE PRIMARY FOREIGN BODY FROM THE PATIENT WHEN THE TIP OF THE SECOND SNARE DEVICE ALSO DETACHED. THE PHYSICIAN STATES THAT USUAL RESISTANCE WAS EXPERIENCED DURING THE REMOVAL PROCEDURE EVEN THOUGH THE FILTER WAS EMBEDDED WITHIN THE WALL OF THE IVC. ORIGINAL IMPLANT DATE IN UNKNOWN. NO ADDITIONAL CONSEQUENCES TO REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13588588 ↗MalfunctionJan 27, 2022Material Separation; Material Separation
THE ACCOUNT ALLEGES THAT DURING A VASCULAR PROCEDURE INVOLVING A SNARE DEVICE, WHEN RETRIEVING THE VASCULAR SNARE FROM WITHIN THE CATHETER, THEY ALSO RETRIEVED SOME TYPE OF TRANSPARENT FOREIGN MATERIAL AS WELL. IT IS CURRENTLY UNKNOWN IF ANY OF THE FOREIGN MATERIAL HAD BEEN INADVERTENTLY INTRODUCED INTO THE PATIENT DURING USE. THE MATERIAL IN QUESTION IS NOT RADIOPAQUE. THE PATIENT WAS DISCHARGED AS EXPECTED WITH NO ADDITIONAL CONSEQUENCES TO REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13370308 ↗MalfunctionNov 18, 2020Fracture; Material Separation; Fracture; Material Separation
THE ACCOUNT ALLEGES THAT DURING A VCF RETRIEVAL PROCEDURE, THE TIP OF THE SNARE DEVICE DETACHED WITHIN THE PATIENT. IT WAS EASY TO SNARE THE HOOK AT THE TOP OF THE VCF BUT THE FEET OF THE FILTER WERE FAIRLY EMBEDDED IN THE WALL OF THE VENA CAVA. THE PHYSICIAN STATES THAT A FAIR AMOUNT OF FORCE WAS BEING APPLIED TO THE SNARE AT THE TIME IT FAILED. THE TIP OF THE SNARE DEVICE WAS SUCCESSFULLY RETRIEVED FROM THE PATIENT. VCF HAD BEEN IMPLANTED 5 YEARS AGO. THE PATIENT TOLERATED THE PROCEDURE WELL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10863882 ↗
Other Device, percutaneous retrieval devices
- Gunther Tulip G13287Cook Incorporated · Device, percutaneous retrieval1 death98 reports
- CloverSnare G53008Cook Incorporated · Device, percutaneous retrieval32 reports
- Indy OTW G51836Cook Incorporated · Device, percutaneous retrieval17 reports
- Aveir™ LSCR111St. Jude Medical, Inc. · Device, percutaneous retrieval2 deaths15 reports
- Bard Snare OUS SRK35Heraeus Medical Components LLC · Device, Percutaneous Retrieval13 reports
- Indy OTW G51835Cook Incorporated · Device, percutaneous retrieval8 reports
- EN Snare® 00884450452462Merit Medical Systems, Inc. · Device, percutaneous retrieval7 reports
- Gunther Tulip G13287Cook Incorporated · Device, percutaneous retrieval6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page