basixCOMPAK™ 00884450498538Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450498538), received between Dec 12, 2025 and Dec 12, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component1
- Inflation Problem1
- Separation Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 12, 2025Inflation Problem; Separation Failure; Detachment of Device or Device Component; Inflation Problem; Separation Failure; Detachment of Device or Device Component
THE ACCOUNT ALLEGES THAT DURING A SHUNT PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE, VASCULAR DILATION WAS PERFORMED USING A KANEKA PTA BALLOON. THE BALLOON WAS PRESSURIZED TO 30 ATM ON TWO OCCASIONS WITHOUT ISSUE. DURING THE THIRD PRESSURIZATION, A POPPING SOUND WAS REPORTED, AND THE PRESSURE GAUGE READING DROPPED TO 0 ATM. THE PLUNGER REMAINED ENGAGED AND DID NOT RETRACT. THE OPERATOR THEN DEPRESSURIZED THE DEVICE BY GRASPING THE LOCK/RELEASE BAR AND PULLING THE PLUNGER HANDLE. THE PROCEDURE WAS COMPLETED USING ANOTHER BALLOON OF THE SAME PART NUMBER AND LOT. THE PROCEDURE WAS COMPLETED WITHOUT REPORTED PATIENT COMPLICATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23791676 ↗
Other Syringe, Balloon Inflation, Exempt devices
- basixCOMPAK™ 00884450638385Merit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt2 recalls4 reports
- basixCOMPAK™ TMerit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt2 recalls0 reports
- basixCOMPAK™ 00884450638521Merit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt2 recalls0 reports
- basixTOUCH™ 00884450621417Merit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt2 recalls0 reports
- basixSKY™ Initial ReleaseMerit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt2 recalls0 reports
- Encore 26 M00566670Boston Scientific Corporation · Syringe, Balloon Inflation, Exempt1 recall26 reports
- basixCOMPAK™ 00884450637524Merit Medical Systems, Inc. · Syringe, Balloon Inflation, Exempt1 recall15 reports
- Encore 26 M0067101140Boston Scientific Corporation · Syringe, Balloon Inflation, Exempt1 recall8 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.