Skip to content

Surfacer®Recalls & reported problems

Merit Medical Systems, Inc. · Class 2

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00884450762158), received between Nov 25, 2025 and Aug 20, 2026 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 3 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem3
  • Material Separation1

Patient problems

  • Hemothorax2
  • Cardiac Arrest1
  • Cardiovascular Dysfunction/Insufficiency1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 20, 2026Material Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50356342 ↗
  • InjuryNov 26, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IN A LITERATURE ARTICLE (BOHLE, 2023), CUSTOMER REPORTS " DURING SURFACER INSIDE-OUT CENTRAL VENOUS RECANALIZATION, PATIENT SUSTAINED RIGHT INTERNAL MAMMARY ARTERY LACERATION WITH MASSIVE HEMOTHORAX AND CARDIOVASCULAR COLLAPSE; MANAGED WITH TRANSFUSION, CHEST TUBE, AND ARTERIAL COIL EMBOLIZATION. DEVICE USE INTRA-PROCEDURE IMPLICATED; ADVANCED IMAGING SUGGESTED INJURY RISK ALONG PROJECTED DEVICE PATH."

    Patient problems: Cardiovascular Dysfunction/Insufficiency; Hemothorax

    MAUDE report 23658628 ↗
  • InjuryNov 25, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IN A LITERATURE ARTICLE (PUPPALA ET AL., 2025), CUSTOMER REPORTS " AN ADVERSE EVENT ASSOCIATED WITH THE SURFACER SYSTEM WAS IDENTIFIED IN A 2025 U.S. CASE REPORT. A PATIENT SUFFERED A CARDIAC ARREST DURING OR FOLLOWING SURFACER PROCEDURE. DETAILS OF RESUSCITATION AND PATIENT OUTCOME WERE NOT SPECIFIED IN THE ABSTRACT BUT WERE TEMPORALLY LINKED TO THE DEVICE USE."

    Patient problems: Cardiac Arrest

    MAUDE report 23645279 ↗
  • InjuryNov 25, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IN A LITERATURE ARTICLE (BOHLE ET AL., 2023), CUSTOMER REPORTS "A 71-YEAR-OLD FEMALE UNDERGOING SURFACER INSIDE-OUT CENTRAL VENOUS CATHETER PLACEMENT FOR THORACIC CENTRAL VENOUS OCCLUSION EXPERIENCED A NEAR-FATAL ARTERIAL INJURY. DURING ADVANCEMENT OF THE DEVICE, THE RIGHT INTERNAL MAMMARY ARTERY WAS INADVERTENTLY LACERATED, RESULTING IN MASSIVE BLEEDING AND CARDIOVASCULAR COLLAPSE. THE PATIENT REQUIRED TRANSFUSION, CHEST TUBE PLACEMENT, AND COIL EMBOLIZATION OF THE INJURED ARTERY. IMAGING REVIEW POST-PROCEDURE REVEALED THE TRAJECTORY OF THE DEVICE INTERSECTED THE ARTERY, INDICATING POTENTIAL FOR INJURY DUE TO ANATOMICAL VARIATION. THE EVENT RESULTED IN HEMOTHORAX AND PROLONGED HOSPITALIZATION, BUT THE PATIENT ULTIMATELY RECOVERED."

    Patient problems: Hemothorax

    MAUDE report 23645271 ↗

Other Reverse central venous recanalization system devices

All Reverse central venous recanalization system devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.