Duo-Flow® XTP116IJSRecalls & reported problems
Medical Components, Inc. · 11.5F X 15CM RAULERSON PRE-CURVED Duo-Flow® IJ DOUBLE LUMEN CATHETER WITH SOFT TIP SET · Class 2
- Adverse event reports
- 2
- Deaths reported
- 2
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884908059144), received between Jun 29, 2021 and Jun 29, 2021 — classified as 2 deaths.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Cardiac Arrest2
- Hematoma1
- Laceration(s)1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
DeathJun 29, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT HAD AORTIC VALVE REPLACEMENT AND CORONARY BYPASS SURGERY ON (B)(6) 2021. POST OPERATIVELY IN THE CRITICAL CARE UNIT, HE PRESENTED WITH DETERIORATION OF KIDNEY FUNCTION. ON (B)(6) 2021 A PERCUTANEOUS DIALYSIS CATHETER WAS INSERTED THROUGH ULTRASOUND-GUIDED RIGHT INTERNAL JUGULAR VEIN, TO PERFORM DIALYSIS. AFTER INSERTION, PATIENT SITS DOWN. HEMODYNAMICALLY AND RESPIRATORY STABLE. WHEN STARTING DIALYSIS, AIR ASPIRATION WAS OBSERVED THROUGH ONE OF THE LIGHTS. ON CHEST RADIOGRAPHY, THE CATHETER APPEARS TO BE NORMALIZED, SO IT WAS DECIDED TO REMOVE IT AND INSERT A NEW ONE. AFTER REMOVING THE CATHETER, THE PATIENT PRESENTED RAPID CLINICAL DETERIORATION, WITH CARDIAC ARREST. RESUSCITATION MANEUVERS AND EMERGENT STERNOTOMY REVEALED THE EXISTENCE OF A LARGE HEMATOMA IN THE RIGHT HEMOTHORAX. REGULATED SURGICAL REVISION WAS PERFORMED, NO VASCULAR LESION WAS OBSERVED, NOR NEW BLEEDING. UNFAVORABLE SUBSEQUENT EVOLUTION, WITH CEREBRAL HYPOXIA, AND DEATH TWO DAYS LATER.
Patient problems: Cardiac Arrest; Hematoma
MAUDE report 12087683 ↗DeathJun 29, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
CRITICAL PATIENT, SEDATED AND ON MECHANICAL VENTILATION, WITH MEDIASTINAL DRAINAGE. ULTRASOUND-GUIDED PUNCTURE IN THE LEFT INTERNAL JUGULAR VEIN. INSERTION OF CATHETER WITHOUT APPARENT INCIDENTS. VENOUS BLOOD REFLUX THROUGH BOTH LUMENS OF THE CATHETER. SEALED WITH 1% HEPARIN. MOBILIZATION AND HYGIENE OF THE PATIENT IS CARRIED OUT. TWO HOURS LATER, BEFORE STARTING THERAPY, MASSIVE BLEEDING FROM THE MEDIASTINAL DRAINS, WITH CARDIAC ARREST. EMERGING STERNOTOMY, INNOMINATE VEIN LACERATION IS OBSERVED.
Patient problems: Cardiac Arrest; Laceration(s)
MAUDE report 12086590 ↗
Other CATHETER, HEMODIALYSIS, NON-IMPLANTED devices
- MAHURKAR 8888135191Mozarc Medical US LLC · CATHETER, HEMODIALYSIS, NON-IMPLANTED1 recall175 reports
- MAHURKAR 8888135241Mozarc Medical US LLC · CATHETER, HEMODIALYSIS, NON-IMPLANTED1 recall1 death100 reports
- ARROW IPN036723Teleflex Incorporated · CATHETER, HEMODIALYSIS, NON-IMPLANTED2 recalls2 reports
- DuoGlide catheter 5625240Bard Access Systems, Inc. · CATHETER, HEMODIALYSIS, NON-IMPLANTED2 recalls1 report
- ARROW IPN036412Teleflex Incorporated · CATHETER, HEMODIALYSIS, NON-IMPLANTED2 recalls1 report
- ARROW IPN036419Teleflex Incorporated · CATHETER, HEMODIALYSIS, NON-IMPLANTED2 recalls0 reports
- ARROW IPN927343Teleflex Incorporated · Catheter, hemodialysis, non-implanted2 recalls0 reports
- ARROW IPN036428Teleflex Incorporated · CATHETER, HEMODIALYSIS, NON-IMPLANTED2 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.