Skip to content

TRIO-CT® AS01135201Recalls & reported problems

Medical Components, Inc. · 13.5F X 20CM TRIO-CT® TRIPLE LUMEN CATHETER BASIC SET · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884908133219), received between Aug 1, 2023 and Apr 12, 2024 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Use of Device Problem1

Patient problems

  • Cardiac Arrest1
  • Embolism/Embolus1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 12, 2024Use of Device Problem; Use of Device Problem

    PATIENT WAS TO HAVE A CT GUIDED G-TUBE PLACEMENT. DURING SCOUT FILM, AN AIR EMBOLUS WAS DETECTED IN THE RIGHT VENTRICLE. PATIENT WAS IMMEDIATELY REMOVED FROM THE CT TABLE AND THE G-TUBE PLACEMENT WAS DEFERRED. PATIENT WAS PLACED IN LEFT LATERAL DECUBITUS POSITION, PLACE ON 100% OXYGEN NONREBREATHER, AND ATTEMPTS MADE TO ASPIRATE THE AIR VIA THE PATIENT'S INDWELLING HEMODIALYSIS CATHETER. PATIENT BECAME INCREASINGLY HYPOXIC AND DETERIORATED WITH LOSS OF PULSE. CODE WAS IMMEDIATELY CALLED. PATIENT SURVIVED. MENTATION APPROPRIATE AND FOLLOWING COMMANDS.

    Patient problems: Cardiac Arrest; Embolism/Embolus

    MAUDE report 19098424 ↗
  • MalfunctionAug 1, 2023Break; Break

    TRIPLE LUMEN VASCATH CATHETER WAS INSERTED BUT THE GUIDEWIRE WAS DIFFICULT TO REMOVE. THE GUIDEWIRE BROKE WHILE ATTEMPTING TO REMOVE. THE REST OF THE GUIDEWIRE CAME OUT WITH REMOVAL OF VASCATH. A SECOND VASCATH CATHETER WAS INSERTED AND THE SAME SCENARIO OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17433969 ↗

FDA clearance and classification

The FDA regulates product code NIE (catheter, hemodialysis, triple lumen, non-implanted) under 21 CFR 876.5540 as a Class II device. 21 CFR 876.5540 ↗

Devices of this type normally need 510(k) clearance before sale.

The FDA lists this type of device as life-sustaining or life-supporting.

Common questions about the TRIO-CT® AS01135201

Has the TRIO-CT® AS01135201 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00884908133219), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the TRIO-CT® AS01135201?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Aug 1, 2023 and Apr 12, 2024. In those reports, the most common specific device problems are “Break” (1) and “Use of Device Problem” (1); the most common patient problems are “Cardiac Arrest” (1) and “Embolism/Embolus” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TRIO-CT® AS01135201?

None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the TRIO-CT® AS01135201, and is it still sold?

The FDA's device database lists Medical Components, Inc. as the company responsible for it (brand TRIO-CT®, model AS01135201). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED devices

All CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page