CD HORIZON® Spinal System 76446540Recalls & reported problems
Medtronic Sofamor Danek, Inc. · BONE SCREW 76446540 MULT AXIAL 6.5X40 TI · Class 2 · Implant
All models of CD HORIZON Spinal System (342)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00885074134758), received between Jan 2, 2025 and Jan 2, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K042025); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- Intraoperative Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 2, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
INFORMATION WAS RECEIVED FROM A REGULATORY BODY VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WHO UNDERWENT THORACOLUMBAR FUSION, POSTERIOR APPROACH FOR LUMBAR SPONDYLOLISTHESIS WITH SPINAL STENOSIS. IT WAS REPORTED THAT WHEN THE SCREWS WERE IMPLANTED, THE TAILS OF 3 SCREWS FELL OFF. THEN THE SCREWS WERE SCREWED OUT, AND THE SCREW OF A NEW MODEL WERE UNIFORMLY REPLACED AND RE-IMPLANTED, WHICH PROLONGED THE OPERATION TIME AND INCREASED THE PAIN OF THE PATIENT. THE OPERATION WAS EXTENDED FOR 10 MINUTES, THE PATIENT DID NOT CAUSE SERIOUS INJURY, THE SCREW WAS REPLACED DURING THE OPERATION, AND THE OPERATION WAS SUCCESSFULLY COMPLETED. NO FURTHER COMPLICATIONS WERE REPORTED/ANTICIPATED.
Patient problems: Intraoperative Pain
MAUDE report 21056810 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K042025. One submission often covers many models, so check the product and lot details in each record.
- Z-0465-2012 · Nov 30, 2011 · TerminatedCD HORIZON (R) Spinal System, MULTI-AXIAL SCREW FOR 5.5mm ROD W/REDUCTION HEAD, Size 6.5mm X 40mm, Mat'l TITANIUM ALLOY, REF X1010484, Rx only, Medtronic Sofamor Danek USA, 1800 Py
- Z-0464-2012 · Nov 30, 2011 · TerminatedCD HORIZON (R) Spinal System, MULTI-AXIAL SCREW FOR 5.5mm ROD W/DUAL LEAD THREAD, Size 6.5mm X 40mm, Mat'l TITANIUM ALLOY, REF X0809439, Rx only, Medtronic Sofamor Danek USA, 1800
- Z-2875-2011 · Jun 28, 2011 · TerminatedCD HORIZON (R) LEGACY (TM) MAS, REF 75445540, pedicle screw, Rx only, Medtronic Sofamor Danek USA, 1800 Pyramid Place, Memphis, TN 38132 Intended to help provide immobilization a
- Z-2878-2011 · Jun 28, 2011 · TerminatedATLANTIS (R) Self-Tapping Variable Angle Screw, Rx only, Medtronic Sofamor Danek USA, 1800 Pyramid Place, Memphis, TN 38132 Intended to help provide immobilization and stabilizat
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Mariner RDX MX1-000040Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Mariner RDX MX1-000030Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430112Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430224Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page