LEGION 71934056Recalls & reported problems

Smith & Nephew, Inc. · LEGION POROUS Hyrdoxyapatite TIBIAL Baseplate SIZE 4 LEFT · Class 2 · Implant

All models of LEGION (446)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00885556143452), received between Mar 10, 2020 and Oct 9, 2025 — classified as 3 injuries.

The most frequently reported specific device problem is “Unintended Movement” (1 report).

1 other recall cover devices cleared under the same FDA submission (K100897, K230653); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Unintended Movement1

Patient problems

  • Arthritis2
  • Erosion1
  • Injury1
  • Pain1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AFTER A TKA HAD BEEN PERFORMED ON (B)(6) 2015, PATIENT COMPLAINT OF LEFT KNEE PAIN. PATIENT WAS SEEN IN CLINIC AND FOUND TO HAVE OSTEOARTHRITIS OF THE LEFT KNEE IN THE PATELLOFEMORAL ARTICULATION. THIS ADVERSE EVENT WAS ADDRESSED BY PERFORMING A REVISION SURGERY ON (B)(6) 2025, DURING WHICH THE LEGION POROUS HA TIBIAL BASE SZ 4 LT WAS EXCHANGED. PATIENT'S OUTCOME WAS RECOVERED.

    Patient problems: Arthritis

    MAUDE report 23263123 ↗
  • InjuryOct 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2015, THE PATIENT EXPERIENCED PAIN AND WAS FOUND TO HAVE A SEVERE PATELLOFEMORAL OSTEOARTHRITIS IN THE LEFT KNEE. THIS ADVERSE EVENT WAS TREATED BY A REVISION SURGERY ON (B)(6) 2025, IN WHICH ONE (1) LEGION POROUS HA TIBIAL BASE SZ 4 LT WAS REVISED. THE ADVERSE EVENT WAS RESOLVED. THIS ADVERSE EVENT WAS IDENTIFIED DURING A CLINICAL STUDY.

    Patient problems: Arthritis; Erosion; Pain

    MAUDE report 23251605 ↗
  • InjuryMar 10, 2020Unintended Movement; Unintended Movement

    IT WAS REPORTED THAT THE PATIENT PRESENTED ASEPTIC LOOSENING ON THE TIBIAL BASEPLATE OF THE LEFT KNEE. THIS WAS NOTICED WHEN THE RADIOGRAPHIC IMAGES SHOWED RADIOLUCENCIES ON THAT COMPONENT. IT IS UNKNOWN HOW THE COMPLICATION WAS TREATED.

    Patient problems: Injury

    MAUDE report 9814225 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K100897, K230653. One submission often covers many models, so check the product and lot details in each record.

  • Z-2621-2023 · Aug 31, 2023 · Open, Classified
    smith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint

Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page