Skip to content

EVOS 71174926Recalls & reported problems

Smith & Nephew, Inc. · FIXED HANDLE T7 SCREW DRIVER · Class 1

All models of EVOS (190)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00885556387597), received between Jun 26, 2020 and Feb 1, 2023 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break1
  • Fracture1
  • Material Deformation1
  • Naturally Worn1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 1, 2023Fracture; Fracture

    IT WAS REPORTED THAT, DURING AN INTERNAL FIXATION SURGERY, A FIXED HANDLE T7 SCREW DRIVER BROKE WHILE TRYING TO HEW THE PLATE. ISSUE OCCURRED OUTSIDE THE PATIENT. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY. PATIENT WAS NOT HARMED AS CONSEQUENCE OF THIS PROBLEM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16278168 ↗
  • MalfunctionJun 18, 2021Material Deformation; Material Deformation

    IT WAS REPORTED THAT, A FIXED HANDLE T7 SCREW DRIVER IS STRIPPED DUE TO USE. AS THIS WAS NOTICED DURING INSPECTION ACTIVITIES, NO PATIENT WAS INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12022901 ↗
  • MalfunctionFeb 17, 2021Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT, SCREWDRIVERS ARE WORN DOWN SO THEY DON'T FIT IN THE SCREWS PROPERLY. THIS WAS NOTICED DURING INSPECTION. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11341044 ↗
  • InjuryJun 26, 2020Break; Break

    IT WAS REPORTED THAT A FIXED HANDLE T-7 SCREW DRIVER IS STRIPPED AND WILL NOT TIGHTEN THE SCREW DURING DISTAL HUMERUS PROCEDURE. THE EVENT OCCURRED DURING SURGERY AND PROCEDURE WAS COMPLETED USING AN S AND N BACK UP DEVICE. USED MINI EVOS FOR LAG. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10203564 ↗

Other SCREWDRIVER devices

All SCREWDRIVER devices →

Sources and updates