Skip to content

JOURNEY 74025631Recalls & reported problems

Smith & Nephew, Inc. · JOURNEY II CR INSERT XLPE RIGHT SIZE 3-4 9MM · Class 2 · Implant

All models of JOURNEY (566)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00885556422601), received between Nov 30, 2017 and Jun 13, 2024 — classified as 7 injuries, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (4 reports).

1 other recall cover devices cleared under the same FDA submission (K121443, K230653); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information4
  • Adverse Event Without Identified Device or Use Problem1
  • Fracture1
  • Patient Device Interaction Problem1
  • Unsealed Device Packaging1

Patient problems

  • Injury4
  • No Clinical Signs, Symptoms or Conditions2
  • No Information1
  • Unspecified Infection1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 13, 2024Unsealed Device Packaging; Unsealed Device Packaging

    IT WAS REPORTED THAT DURING A TKA SURGERY, WHEN THE BOX OF ONE (1) JRNY II CR ISRT XLPE RT SZ 3-4 9MM WAS OPENED, IT WAS REALIZED THAT BOTH STERILE PACKAGING OF THE POLY HAD BEEN OPENED. IT COULD BE A MANUFACTURING DEFECT, OR IT COULD BE CAUSED BY THE WAY IT WAS STORED. THE PROCEDURE WAS RESUMED WITHOUT ANY DELAY USING AN S+N BACKUP DEVICE. NO INJURY WAS REPORTED AS A CONSEQUENCE OF THIS ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19532359 ↗
  • InjuryNov 26, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT UNDERWENT A TOTAL KNEE REPLACEMENT ON (B)(6) 2019 AND WAS UNABLE TO REHAB. SYNOVECTOMY WAS PERFORMED AND THE INSERT WAS EXCHANGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10912851 ↗
  • InjuryJun 10, 2020Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT A ORTHOPEDIC SURGERY HAD TO BE PERFORMED DUE TO ARTHROFIBROSIS ON THE RIGHT KNEE. REHABILITATION THERAPY FOLLOWING THE TKA WITH JOURNEY II CR TKS WAS PERFORMED ON (B)(6) 2016.

    Patient problems: Injury

    MAUDE report 10141408 ↗
  • InjuryMar 17, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT DEVELOPED CELLULITIS IN THE RIGHT LOWER EXTREMITY. THE EVENT WAS TREATED VIA MEDICATION AND MEDICAL INTERVENTION TO PREVENT A LIFE-THREATENING CONDITION IN THE SUBJECT

    Patient problems: Unspecified Infection

    MAUDE report 9842192 ↗
  • InjuryMar 13, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT SUFFERED FROM RIGHT KNEE ARTHROFIBROSIS AFTER A TKR. THE EVENT WAS RESOLVED VIA MUA, WITH RESIDUAL EFFECTS.

    Patient problems: Injury

    MAUDE report 9832149 ↗
  • InjurySep 6, 2019Fracture; Fracture

    IT WAS REPORTED THAT THE PATIENT PRESENTED A RIGHT FOOT FRACTURE. ADVERSE EVENT HAS A POSSIBLE RELATION TO DEVICE. NO PROCEDURE DETAILS REPORTED. EVENT WAS RESOLVED WITH CONSERVATIVE APPROACH.

    Patient problems: Injury

    MAUDE report 8969154 ↗
  • InjuryAug 7, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A MANIPULATION UNDER ANESTHESIA DUE TO ARTHROFIBROSIS.

    Patient problems: Injury

    MAUDE report 8868017 ↗
  • InjuryNov 30, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    A JOURNEY CR RIGHT 9MM INSERT WAS EXCHANGED FOR A JOURNEY RIGHT CR 15 MM DEEP DISHED INSERT FOR MORE STABILIZATION. THE PCL WAS ALSO COMPROMISED.

    Patient problems: No Information

    MAUDE report 7073523 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K121443, K230653. One submission often covers many models, so check the product and lot details in each record.

  • Z-2621-2023 · Aug 31, 2023 · Open, Classified
    smith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →