Skip to content

REDAPT 71354723Recalls & reported problems

Smith & Nephew, Inc. · REDAPT 240MM SLEEVELESS REVISION STEM SIZE 16 HIGH OFFSET · Class 2 · Implant

All models of REDAPT (89)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00885556579459), received between Sep 12, 2023 and Sep 12, 2023 — classified as 1 injury.

1 other recall cover devices cleared under the same FDA submission (K151902, K211176); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 12, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A THR SURGERY WAS PERFORMED, THE PATIENT EXPERIENCED UNSPECIFIED SYMPTOM DUE TO FAILED GREATER TROCHANTER FIXATION IN PREVIOUS SURGERY AND SUBSEQUENT STEM SUBSIDENCE. THIS ADVERSE EVENT WAS TREATED BY A REVISION SURGERY ON (B)(6) 2023, BUT IT WAS CANCELLED DUE TO THE SURGEON BEING UNWELL AND UNAVAILABLE TO PERFORM SURGERY ON THE DAY, SO IT WAS BOOKED TO (B)(6) 2023 IN WHICH THE STEM SUBSIDENCE RESULTED IN REDUCED LEG LENGTH AND AN INCISION WAS MADE. IN ADDITION, THE REDAPT SLVLS MONO STEM 240MM SZ 16 HO WAS EXCHANGED. PATIENT'S CURRENT HEALTH STATUS IS UNKNOWN.

    Patient problems: Insufficient Information

    MAUDE report 17730495 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K151902, K211176. One submission often covers many models, so check the product and lot details in each record.

  • Z-0326-2025 · Oct 15, 2024 · Open, Classified
    Tandem Intl Bipolar Cocr Shell/UHMWPE Liner, TI-6AL-4V Retaining Ring, 28MM I.D. 46 MM O.D., REF 71324046, sterile, femoral head bipolar component of the Tandem Bipolar Hip System.

Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices

All Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page