REDAPT 71352354Recalls & reported problems
Smith & Nephew, Inc. · REDAPT MODULAR SHELL 54MM · Class 2 · Implant
All models of REDAPT (89)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00885556657836), received between Nov 12, 2022 and Sep 10, 2025 — classified as 4 injuries.
The most frequently reported specific device problem is “Biocompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Biocompatibility1
Patient problems
- Anemia1
- Cellulitis1
- High metal ion levels1
- Thrombosis/Thrombus1
- Unspecified Infection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjurySep 10, 2025Biocompatibility; Biocompatibility
IT WAS REPORTED THAT, AFTER A THR FIRST REVISION SURGERY WAS PERFORMED ON (B)(6) 2020 DUE TO DISLOCATION AND S+N DEVICES WERE IMPLANTED, AN ADDITIONAL REVISION SURGERY IS REQUIRED IN THE NEAR FUTURE, AS THE PATIENT IS EXPERIENCING ELEVATED METAL ION LEVELS.
Patient problems: High metal ion levels
MAUDE report 23017713 ↗InjurySep 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A LEFT HIP THA CONVERSION SURGERY ON (B)(6) 2022, DUE TO A NONUNION OF INTERTROCHANTERIC FEMUR FRACTURE WITH SCREW CUT-OUT. DURING THIS PROCEDURE, A REDAPT ACETABULAR AND FEMORAL SYSTEM WERE IMPLANTED. THE IDENTITY OF THE PRIMARY FIXATION SYSTEM IS UNKNOWN. THE PATIENT SUFFERED FROM CELLULITIS ON (B)(6) 2022 AND REQUIRED READMISSION TO THE HOSPITAL. THERE IS NO FURTHER INFORMATION AT THIS TIME. THE CURRENT STATE OF HEALTH OF THE PATIENT IS UNKNOWN.
Patient problems: Cellulitis
MAUDE report 20241331 ↗InjurySep 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY OF THE LEFT HIP ON (B)(6) 2022, DUE TO SUBSIDENCE AND LOOSENING FOLLOWING LEFT TOTAL HIP ARTHROPLASTY. DURING THE REVISION SURGERY, THE PRIMARY THA SYSTEM WAS EXPLANTED AND REPLACED WITH A THA ACETABULAR REDAPT SYSTEM AND A REDAPT FEMORAL SYSTEM. THE IDENTITY OF THE HIP SYSTEM IMPLANTED BEFORE THIS REVISION SURGERY IS UNKNOWN. AS REPORTED, THE PATIENT SUFFERED FROM ACCUTE POST OP HEMORRHAGE ANEMIA DURING HER STAY IN THE HOSPITAL. ALSO, ON (B)(6) 2022 THE PATIENT KEPT EXPERIENCING ANEMIA AND SUFFERED FROM DVT. THE ISSUE RESULTED IN THE READMISSION OF THE PATIENT INTO THE HOSPITAL. THERE IS NO FURTHER INFORMATION AT THIS TIME. THE CURRENT STATE OF HEALTH OF THE PATIENT IS UNKNOWN.
Patient problems: Anemia; Thrombosis/Thrombus
MAUDE report 20238984 ↗InjuryNov 12, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, AFTER A REDAPT THR SURGERY PERFORMED ON (B)(6) 2021, THE PATIENT UNDERWENT A REVISION SURGERY ON (B)(6) 2022, DUE TO INFECTION. ALL COMPONENTS WERE EXTRACTED. CURRENT HEALTH STATUS OF THE PATIENT IS UNKNOWN. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: Unspecified Infection
MAUDE report 15785906 ↗
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous devices
- Accolade 6021-0537Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous46 reports
- PROFEMUR® PHAC1252Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous37 reports
- Accolade 6020-0335Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous35 reports
- OXINIUM 71342340Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous32 reports
- EXETER 0580-1-351Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous29 reports
- INSTRUMENT 2101-0200Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous27 reports
- REFLECTION 71330001Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous20 reports
- Accolade 6720-0330Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous18 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page