Skip to content

AETOS Shoulder System LNR-0990-200-380SRecalls & reported problems

Smith & Nephew, Inc. · 38MM REVERSE LINER PLS 0 SML · Class 2 · Implant

All models of AETOS Shoulder System (44)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00885556810170), received between Mar 26, 2024 and Feb 25, 2026 — classified as 4 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated4
  • Material Deformation1

Patient problems

  • Joint Dislocation3
  • Failure of Implant1
  • Joint Laxity1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 25, 2026Device Dislodged or Dislocated

    IT WAS REPORTED THAT, AFTER RTSA SURGERY HAD BEEN PERFORMED ON (B)(6) 2025, THE PATIENT EXPERIENCED A JOINT DISLOCATION DUE TO A DISASSOCIATION OF THE META HUMERAL STEM SIZE 1 S WITH THE 38MM REVERSE LINER +0 S. THIS ADVERSE EVENT WAS TREATED BY A REVISION SURGERY ON (B)(6) 2026, IN WHICH THE META HUMERAL STEM SIZE 1 S AND THE 38MM REVERSE LINER +0 S WERE REMOVED AND REPLACED WITH NEW COMPONENTS. CURRENT PATIENT'S HEALTH STATUS IS UNKNOWN.

    Patient problems: Joint Dislocation

    MAUDE report 24441672 ↗
  • InjuryOct 29, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT, AFTER A TSA SURGERY HAD BEEN PERFORMED ON (B)(6) 2024, THE PATIENT EXPERIENCED A SHOULDER DISLOCATION AROUND ON (B)(6) 2024. THIS ADVERSE EVENT WAS TREATED WITH A REVISION SURGERY ON (B)(6) 2024, IN WHICH THE 38MM REVERSE LINER +0 S AND THE 38MM GLENOSPHERE CONCENTRIC WERE EXCHANGED FOR A 42MM GLENOSPHERE WITH THE CORRESPONDING POLY LINER. UPON EXTRACTION NO DISSOCIATION OR IMPLANT MALFUNCTION WAS NOTED. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.

    Patient problems: Joint Laxity

    MAUDE report 20556670 ↗
  • InjuryApr 1, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT, AFTER A TOTAL SHOULDER ARTHROPLASTY SURGERY WAS PERFORMED ON (B)(6) 2023, THE PATIENT EXPERIENCED POLY DISSOCIATION FOR THE THIRD TIME. THIS ADVERSE EVENT WAS ADDRESSED BY A REVISION SURGERY ON (B)(6) 2024, DURING WHICH ALL HUMERAL COMPONENTS WERE REMOVED AND REPLACED WITH TORNIER FLEX COMPONENTS (COMPETITOR'S DEVICES). UPON INSPECTION OF THE DEVICES, IT WAS NOTICED THAT A 38MM REVERSE LINER +0 S HAD SEVERAL WRAPS AND DEFECTS ALONG THE OUTER EDGES. THE PATIENT'S CURRENT HEALTH STATUS IS UNKNOWN.

    Patient problems: Joint Dislocation

    MAUDE report 19012319 ↗
  • InjuryMar 26, 2024Device Dislodged or Dislocated; Material Deformation; Device Dislodged or Dislocated; Material Deformation

    IT WAS REPORTED THAT, AFTER A SHOULDER SURGERY HAD BEEN PERFORMED ON (B)(6) 2023, PATIENT EXPERIENCED DISLOCATION. DURING PROCEDURE, IT WAS OBSERVED THAT THE REVERSE LINER WAS ABLE TO ROCK SLIGHTLY IN THE STEM AND THAT IT WAS SEVERELY DEFORMED FROM THE DISLOCATION. THIS ADVERSE EVENT WAS ADDRESSED BY REVISION SURGERY ON (B)(6) 2024, TO EXCHANGE THE 38MM REVERSE LINER +0 S. PATIENT'S CURRENT HEALTH IS UNKNOWN.

    Patient problems: Failure of Implant; Joint Dislocation

    MAUDE report 18977082 ↗

Other PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED devices

All PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED devices →

Sources and updates