IPure B1PC (clear), +19.00DRecalls & reported problems

Hoya Medical Singapore Pte. Ltd. · Foldable, posterior chamber intraocular lens (IOL), preloaded in an injector that automatically folds the lens as it is advanced, prior to insertion. Single use. · Class 3 · Implant

All models of IPure (24)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00886158017189), received between Mar 23, 2022 and Mar 4, 2024 — classified as 4 injuries.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Material Split, Cut or Torn1
  • Sharp Edges1
  • Unintended Ejection1

Patient problems

  • Failure of Implant3
  • Capsular Bag Tear1
  • Hyphema1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 4, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN USA DAMAGED HAPTIC AFTER IMPLANTATION PROBLEM CODE: A0414, MATERIAL SPLIT CUT OR TORN TRAILING; DR IMPLANTED LENS TRAIL HAPTIC BROKEN NOTICED DURING SURGERY LENS HAD TO BE EXPLANTED AND REPLACED WITH A SULCUS LENS JJ ZA9003 PATIENT HEALTH NOT IMPACTED; NO PERMANENT OR NEGATIVE IMPACT ON PATIENT HEALTH EXPECTED EXPLANTATION DATE: (B)(6) 2023.

    Patient problems: Failure of Implant

    MAUDE report 18831007 ↗
  • InjuryAug 25, 2022Unintended Ejection; Unintended Ejection

    INTRA-OPERATIVE COMPLICATIONS; IOL RELEASE ISSUE. SURGEON STATED THAT LENS UNFOLDED VERY FAST, LENS HAD ALREADY STARTED TO UNFOLD AS THE LENS ENTERED THE CAPSULE. SOME BLEEDING OF THE IRIS OCCURRED WHILE TRYING TO PUT THE LENS INTO THE BAG. SURGEON WAS NOT ABLE TO GET THE LENS INTO THE BAG WITHOUT THE POTENTIAL FOR FURTHER COMPLICATIONS. DEVICE WAS EXPLANTED AND REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY. PATIENT IMPACT: DEVICE EXPLANTATION. PATIENT HAS RECOVERED AND IS FINE.

    Patient problems: Failure of Implant; Hyphema

    MAUDE report 15294441 ↗
  • InjuryMar 24, 2022Break; Break

    DAMAGED HAPTIC AFTER IMPLANTATION HAPTIC WAS BROKEN WHEN THEY INSERTED LENS. DR HAD TO ENLARGE INCISION TO REMOVE THE HAPTIC. DR THEN EXPLANTED THE LENS. PATIENT HEALTH NOT IMPACTED; PATIENT HAS RECOVERED AND IS FINE.

    Patient problems: Failure of Implant

    MAUDE report 13875053 ↗
  • InjuryMar 23, 2022Sharp Edges; Sharp Edges

    INTRA-OPERATIVE COMPLICATIONS. POSTERIOR CAPSULE RUPTURE. DOCTOR REPORTED THAT SOMETHING HAPPENED IN THE PREPPING OF THE LENS OR IN THE INJECTOR THAT IS CUTTING THE LENS LEADING HAPTIC. THIS IS CREATING A SHARP EDGE THAT IS CAUSING THE POSTERIOR CAPSULE TO TEAR WHEN THE SHARP EDGE ON THE HAPTIC COMES IN CONTACT WITH IT. LENS STILL IN THE EYE VIA REVERSE OPTIC CAPTURE. PATIENT HAS RECOVERED AND IS FINE; PATIENT HAS 2020 AND 2030 UNCORRECTED.

    Patient problems: Capsular Bag Tear

    MAUDE report 13862355 ↗

Other Intraocular Lens devices

All Intraocular Lens devices →