IPure B1PC (clear), +20.00DRecalls & reported problems

Hoya Medical Singapore Pte. Ltd. · Foldable, posterior chamber intraocular lens (IOL), preloaded in an injector that automatically folds the lens as it is advanced, prior to insertion. Single use. · Class 3 · Implant

All models of IPure (24)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00886158017202), received between Mar 24, 2022 and Dec 29, 2023 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Material Split, Cut or Torn” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Split, Cut or Torn2
  • Sharp Edges2
  • Break1

Patient problems

  • Failure of Implant4
  • Capsular Bag Tear2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 29, 2023Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN USA. DAMAGED HAPTIC AFTER IMPLANTATION. LENS WAS CUT IN HALF AND EXPLANTED. PATIENT HEALTH NOT IMPACTED. PATIENT HASRECOVERED AND IS FINE. IMDRF CODE: A0414, MATERIAL SPLIT CUT OR TORN. IOL WAS EXPLANTED ON (B)(6) 2023.

    Patient problems: Failure of Implant

    MAUDE report 18418795 ↗
  • InjuryJul 11, 2023Sharp Edges; Sharp Edges

    INTRA-OPERATIVE COMPLICATIONS: POSTERIOR CAPSULE RUPTURE. IT WAS REPORTED: LENS ON FIELD; POSTERIOR CAPSULE BREAK; COULD NOT USE LENS. PATIENT HEALTH NOT IMPACTED; PATIENT HAS RECOVERED AND IS FINE.

    Patient problems: Capsular Bag Tear

    MAUDE report 17297392 ↗
  • InjuryJun 7, 2023Material Split, Cut or Torn; Material Split, Cut or Torn

    DAMAGED HAPTIC AFTER IMPLANTATION. THE DOCTOR WAS INSERTING THE IOL INTO THE LEFT EYE OF PATIENT AND THE HAPTIC BROKE IN THE EYE. THE IOL WAS EXPLANTED, AND THEN INSERTED ANOTHER IOL AND SUCCESSFULLY. PATIENT IMPACT: EXPLANTATION. PATIENT HEALTH NOT IMPACTED; PATIENT HAS RECOVERED AND IS FINE.

    Patient problems: Failure of Implant

    MAUDE report 17080622 ↗
  • InjuryFeb 21, 2023Sharp Edges; Sharp Edges

    DR. INSERTED THE LENS INTO THE BAG AND THE BAG TORE. THE DOCTOR FEELS THAT THE LENS HAD SHARP EDGE THAT CAUSED THE BAG TO RIP. LENS WAS EXPLANTED. PATIENT HEALTH WAS NOT IMPACTED.

    Patient problems: Capsular Bag Tear; Failure of Implant

    MAUDE report 16410688 ↗
  • MalfunctionMar 24, 2022Break; Break

    DAMAGED HAPTIC AFTER IMPLANTATION HAPTIC WAS BROKEN WHEN THEY INSERTED LENS. DR HAD TO ENLARGE INCISION TO REMOVE THE HAPTIC. DR THEN EXPLANTED THE LENS. PATIENT HEALTH NOT IMPACTED; NO PERMANENT OR NEGATIVE IMPACT ON PATIENT HEALTH EXPECTED.

    Patient problems: Failure of Implant; No Clinical Signs, Symptoms or Conditions

    MAUDE report 13875039 ↗