CLEANER Vac™ 70027518Recalls & reported problems
Argon Medical Devices, Inc. · CLEANER Vac™ Thrombectomy System - 18F OD x 115cm · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00886333227167), received between Jan 16, 2026 and Jan 16, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 16, 2026Fracture
AN ASPIRATION THROMBECTOMY PROCEDURE WAS PERFORMED ON A 31-YEAR-OLD MALE PATIENT WITH ILIOFEMORAL DEEP VEIN THROMBOSIS. POPLITEAL ACCESS WITH MEDTRONIC 20F SENTRANT INTRODUCER, USE OF AEANER VAC SYSTEM, FINDING CALCIFICATION IN THE PROXIMAL SEGMENT OF THE SEGMENT TO BE TREATED AND AN ACUTE THROMBUS OF 4 DAYS' EVOLUTION THE DISTAL SEGMENT, LIOFEMORAL REGION. THE CATHETER SUFFERS MULTIPLE DAMAGES BOTH AT THE TIP AND TWISTING OF THE OTHER DISTAL BODY OF THE ASPIRATION CATHETER. IN THE LAST ATTEMPT TO ASPIRATE. THE TRACKABILITY DILATOR FRACTURED. SO THE PROCEDURE COULD NOT BE COMPLETED WITH 100% SUCCESS.
Patient problems: Insufficient Information
MAUDE report 24100958 ↗
FDA clearance and classification
Cleared through 510(k) K232679 on Jan 19, 2024 (decision: Substantially Equivalent). Submitted by Argon Medical Devices, Inc. as “Cleaner Pro Thrombectomy System; Cleaner Pro Aspiration Catheter with Handpiece; Cleaner Pro Aspiration Canister”. The FDA review took 140 days. FDA record ↗
The FDA regulates product code QEW (peripheral mechanical thrombectomy with aspiration) under 21 CFR 870.5150 as a Class II device. 21 CFR 870.5150 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CLEANER Vac™ 70027518
Has the CLEANER Vac™ 70027518 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00886333227167), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CLEANER Vac™ 70027518?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jan 16, 2026. That report lists device problem “Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CLEANER Vac™ 70027518?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CLEANER Vac™ 70027518 FDA approved?
It was cleared through 510(k) K232679 on Jan 19, 2024. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the CLEANER Vac™ 70027518, and is it still sold?
The FDA's device database lists Argon Medical Devices, Inc. as the company responsible for it (brand CLEANER Vac™, model 70027518). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Peripheral Mechanical Thrombectomy With Aspiration devices
- Indigo System LITNG12HTORQ115-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration4 deaths105 reports
- Indigo System LITNG7XTORQ130-APenumbra, Inc. · Peripheral mechanical thrombectomy with aspiration100 reports
- Indigo System LITNG12XTORQ100-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 death80 reports
- ClotTriever XL Catheter AS-0235Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 recall9 deaths21 reports
- Indigo System LITNGBT7TQ130-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration46 reports
- Indigo System LITNG12HTORQ100-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 death46 reports
- Triever 24 22-101Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration20 deaths34 reports
- ClotTriever Catheter, 16 mm 40-102Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration11 deaths27 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page