Skip to content

AttraX 5015010Recalls & reported problems

Nuvasive, Inc. · AttraX® Putty, 10cc US · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887517241566), received between Aug 25, 2025 and Aug 25, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Migration1

Patient problems

  • Unspecified Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 25, 2025Migration; Migration

    IT WAS REPORTED THAT THE ATTRAX PUTTY MIGRATED POST OPERATIVELY, THE SITE WAS ALSO DISCOVERED TO BE INFECTED WHEN THE PUTTY WAS REMOVED.

    Patient problems: Unspecified Infection

    MAUDE report 22882770 ↗

FDA clearance and classification

Cleared through 510(k) K191974 on Nov 3, 2019 (decision: Substantially Equivalent). Submitted by Nu Vasive, Incorporated as “NuVasive AttraX Putty”. The FDA review took 102 days. FDA record ↗

Cleared through 510(k) K172497 on Nov 24, 2017 (decision: Substantially Equivalent). Submitted by Nu Vasive, Incorporated as “NuVasive AttraX Scaffold”. The FDA review took 98 days. FDA record ↗

Cleared through 510(k) K151584 on Oct 8, 2015 (decision: Substantially Equivalent). Submitted by Progentix Orthobiology BV as “AttraX Putty”. The FDA review took 119 days. FDA record ↗

…and 1 more FDA submissions listed for this device.

The FDA regulates product code MQV (filler, bone void, calcium compound) under 21 CFR 888.3045 as a Class II device. 21 CFR 888.3045 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the AttraX 5015010

Has the AttraX 5015010 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00887517241566), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the AttraX 5015010?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Aug 25, 2025. That report lists device problem “Migration” (1); patient problem “Unspecified Infection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the AttraX 5015010?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the AttraX 5015010 FDA approved?

It was cleared through 510(k) K090641 on Oct 23, 2009; its record lists 4 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the AttraX 5015010 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the AttraX 5015010, and is it still sold?

The FDA's device database lists Nuvasive, Inc. as the company responsible for it (brand AttraX, model 5015010). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other FILLER, BONE VOID, CALCIUM COMPOUND devices

All FILLER, BONE VOID, CALCIUM COMPOUND devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page