Skip to content

CoRoent 6791715Recalls & reported problems

Nuvasive, Inc. · CoRoent® SI Screw, 4x15mm Self-Tap · Class 2 · Implant

All models of CoRoent (64)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887517362421), received between Feb 16, 2018 and Jan 23, 2020 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Fracture” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Fracture2

Patient problems

  • Failure of Implant1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 23, 2020Fracture; Fracture

    ON (B)(6) 2016 PATIENT UNDERWENT AN ANTERIOR CERVICAL DISCECTOMY FUSION PROCEDURE AT C5-6 LEVELS. ON (B)(6) 2017 DURING FOLLOW UP, THE PATIENT WAS EXPERIENCING NECK AND SHOULDER PAIN. RADIOGRAPHS SHOWED NO HARDWARE FAILURE AND BONY IN-GROWTH AT C5-6. ON (B)(6) 2019 RADIOGRAPHS AND A CT SCAN SHOWED ONE OF THE SCREWS WAS BROKEN.

    Patient problems: Pain

    MAUDE report 9623147 ↗
  • MalfunctionFeb 16, 2018Fracture; Fracture

    ON (B)(6) 2015 PATIENT UNDERWENT AN ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C4-T1 LEVELS WITH INTERLOCK CAGES. ON (B)(6) 2016 POSTOPERATIVE FILMS INDICATED A SCREW FRACTURE AT C6 LEVEL. PATIENT IS ASYMPTOMATIC.

    Patient problems: Failure of Implant

    MAUDE report 7277274 ↗

FDA clearance and classification

Cleared through Special 510(k) K231735 on Jul 11, 2023 (decision: Substantially Equivalent). Submitted by Nu Vasive, Incorporated as “NuVasive CoRoent Small Interbody System; NuVasive CoRoent Small Contoured Interbody System; NuVasive CoRoent Small Interlock System; NuVasive CoRoent Small Interlock II System; NuVasive CoRoent Small Ti-C System; NuVasive Cohere Cervical Interbody System”. The FDA review took 27 days. FDA record ↗

Cleared through 510(k) K192582 on Nov 13, 2019 (decision: Substantially Equivalent). Submitted by Nu Vasive, Incorporated as “NuVasive CoRoent Small Interlock System”. The FDA review took 55 days. FDA record ↗

Cleared through 510(k) K170961 on Jun 8, 2017 (decision: Substantially Equivalent). Submitted by Nu Vasive, Incorporated as “NuVasive CoRoent Small Interlock II System”. The FDA review took 69 days. FDA record ↗

…and 3 more FDA submissions listed for this device.

The FDA regulates product code ODP (intervertebral fusion device with bone graft, cervical) under 21 CFR 888.3080 as a Class II device. 21 CFR 888.3080 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: Intended to stabilize cervical spinal segment to promote fusion in order to restrict motion and decrease pain using bone graft.

Common questions about the CoRoent 6791715

Has the CoRoent 6791715 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00887517362421), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the CoRoent 6791715?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Feb 16, 2018 and Jan 23, 2020. In those reports, the most common specific device problem is “Fracture” (2); the most common patient problems are “Failure of Implant” (1) and “Pain” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the CoRoent 6791715?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the CoRoent 6791715 FDA approved?

It was cleared through 510(k) K102547 on Feb 7, 2011; its record lists 6 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the CoRoent 6791715 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the CoRoent 6791715, and is it still sold?

The FDA's device database lists Nuvasive, Inc. as the company responsible for it (brand CoRoent, model 6791715). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Intervertebral fusion device with bone graft, cervical devices

All Intervertebral fusion device with bone graft, cervical devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page