Skip to content

X-CORE 7180027Recalls & reported problems

Nuvasive, Inc. · X-CORE 2 Ti Core, Ø18x21-27mm · Class 2 · Implant

All models of X-CORE (29)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887517426505), received between Jan 18, 2016 and Jan 18, 2016 — classified as 1 injury.

1 other recall cover devices cleared under the same FDA submission (K090176); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Spinal Column Injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 18, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2015 A FEMALE PATIENT UNDER WENT AN XLIF PROCEDURE FOR CORPECTOMY AT L1. AFTER PLACING THE XCORE II THE SURGEON WAS REMOVING THE POSTERIOR VERTEBRAL WALL WHEN THE CHISEL ACCIDENTLY ENTERED THE SPINAL CANAL AND SPINAL FLUID LEAKED. MEP AMPLITUDE DECREASED BUT WAVEFORM WAS DISPLAYED UNTIL CLOSURE OF THE INCISIONS. FOLLOWING CORPECTOMY, POSTERIOR DECOMPRESSION AND SPINAL CORD REPAIR WAS PERFORMED. DURING FOLLOW-UP THE PATIENT REPORTEDLY DEVELOPED PARALYSIS OF THE LOWER EXTREMITIES.

    Patient problems: Spinal Column Injury

    MAUDE report 5375640 ↗

FDA clearance and classification

Cleared through Special 510(k) K090176 on Apr 27, 2009 (decision: Substantially Equivalent). Submitted by Nuvasive, Inc. as “Nuvasive Adjustable Vertebral Body Replacement System”. The FDA review took 94 days. FDA record ↗

The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K090176. One submission often covers many models, so check the product and lot details in each record.

  • Z-0738-2023 · Nov 10, 2022 · Open, Classified
    X-CORE 2 Ti Core, Static. Part of the NuVasive X-Core Expandable VBR System used with spinal fixation.

Common questions about the X-CORE 7180027

Has the X-CORE 7180027 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00887517426505), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the X-CORE 7180027?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jan 18, 2016. That report lists patient problem “Spinal Column Injury” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the X-CORE 7180027?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the X-CORE 7180027 FDA approved?

It was cleared through Special 510(k) K090176 on Apr 27, 2009. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the X-CORE 7180027 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the X-CORE 7180027, and is it still sold?

The FDA's device database lists Nuvasive, Inc. as the company responsible for it (brand X-CORE, model 7180027). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices

All SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page