ReLine 16026545Recalls & reported problems
Nuvasive, Inc. · RELINE MAS Red Screw, 6.5x45mm Poly 2C · Class 2 · Implant
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00887517556639), received between Oct 15, 2018 and May 21, 2026 — classified as 3 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture2
- Adverse Event Without Identified Device or Use Problem1
- Break1
- Malposition of Device1
- Migration or Expulsion of Device1
- Separation Problem1
- Unintended Movement1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Pain3
- Cardiac Arrest1
- Failure of Implant1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 21, 2026Unintended Movement
IT WAS REPORTED THAT A PRIMARY SURGERY TOOK PLACE ON (B)(6) 2026; XLIF AND SPINAL FIXATION AT L2/3/4/5. A SECOND SURGERY WAS PERFORMED BECAUSE THE SCREW HAD DISLODGED. WHEN THE SURGEON ATTEMPTED TO REMOVE THE DISLODGED SCREW, THE SCREW HEAD HAD DETACHED FROM THE SHANK. THE SHANK WAS REMOVED FROM THE BONE, AND THE HEAD AND OTHER PART WERE REMOVED WITH FORCEPS. THERE WAS NO OTHER ADVERSE PATIENT CONSEQUENCES REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25241858 ↗MalfunctionAug 27, 2024Break; Break
ON (B)(6) 2020, A PATIENT UNDERWENT A POSTERIOR SPINAL FIXATION PROCEDURE FROM L2 TO L5. ON (B)(6) 2024 THE PATIENT PRESENTED WITH BACK PAIN. EVALUATION OF THE PATIENT IDENTIFIED THE LEFT L5 PEDICLE SCREW HAD BROKEN. NO INDICATION OF A REVISION SURGERY BEING CONDUCTED OR PLANNED HAS BEEN PROVIDED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Pain
MAUDE report 20077811 ↗InjuryJan 12, 2024Use of Device Problem; Use of Device Problem
IT WAS REPORTED IN A CLINICAL STUDY THAT A PATIENT UNDERWENT AN EXTREME LATERAL INTERBODY FUSION AT L3/5 ON (B)(6), 2022. ON (B)(6), 2022 A CT REVEALED THERE WAS A LEFT L4 PEDICLE BREACH CORRESPONDING WITH LEFT LEG PAIN. TREATMENT WAS REMOVAL OF LEFT-SIDED SCREWS ON (B)(6), 2023.
Patient problems: Pain
MAUDE report 18507506 ↗InjuryOct 14, 2022Malposition of Device; Malposition of Device
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL POSTERIOR FIXATION PROCEDURE FROM T10 TO L1. SUBSEQUENTLY, IT WAS IDENTIFIED THROUGH POSTOPERATIVE CT IMAGING THAT THE RIGHT PEDICLE SCREW AT THE T12 LEVEL WAS MALPOSITIONED MEDIALLY. THE PATIENT DID NOT REPORT EXPERIENCING ANY PAIN OR OTHER ADVERSE SYMPTOMS AS A RESULT OF THE PLACEMENT. APPROXIMATELY SEVEN (7) DAYS LATER, THE PATIENT UNDERWENT A REVISION PROCEDURE TO REMOVE THE MALPOSITIONED SCREW. NO NEW SCREW WAS IMPLANTED INTO THE RIGHT T12 LOCATION. NO FURTHER PATIENT IMPACT WAS REPORTED. NO ADDITIONAL INFORMATION WAS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15611115 ↗MalfunctionAug 12, 2021Fracture; Fracture
ON (B)(6) 2020 A FEMALE PATIENT, OF LARGER SIZE, UNDERWENT A TRANSFORAMINAL LUMBAR INTERBODY FUSION PROCEDURE FROM THE L5-S1 LEVELS. ON A UNKNOWN DATE IT WAS DISCOVERED THE PATIENT EXPERIENCED BILATERAL FRACTURES OF THE IMPLANTS SCREWS AT THE S1 LEVEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12314000 ↗InjuryMar 11, 2021Adverse Event Without Identified Device or Use Problem
A PATIENT UNDERWENT A SPINAL PROCEDURE TO ADDRESS A RUPTURE FRACTURE. AFTER COLLECTING AUTOLOGOUS BONE FROM THE ILIUM A PEDICLE SCREW WAS PERCUTANEOUSLY INSERTED INTO L2. SUBSEQUENTLY THE PATIENT'S BLOOD PRESSURE DROPPED, AND CARDIOPULMONARY ARREST OCCURRED. THERE WAS NO ABNORMALITY IN THE IMAGE AT THE TIME WHEN THE PEDICLE SCREW WAS INSERTED. THE PEDICLE SCREW WAS IMMEDIATELY REMOVED, THE INCISION WAS CLOSED WITH SURGICAL STAPLES, AND THE PATIENT WAS RETURNED TO THE SUPINE POSITION FOR CARDIAC MASSAGE. THE OPERATION WAS DISCONTINUED AND IS NOW RESCHEDULED ON ANOTHER DAY.
Patient problems: Cardiac Arrest
MAUDE report 11465580 ↗MalfunctionDec 4, 2020Fracture; Fracture
ON (B)(6) 2017 A MINIMALLY INVASIVE LUMBAR INTERBODY FUSION WAS PERFORMED AT L3-S1. AN X-RAY ON (B)(6) 2018 REVEALED BROKEN RIGHT PEDICLE SCREW AT S1. THE PATIENT REPORTEDLY HAS BACK PAIN AND IS REQUIRED TO UNDERGO A REVISION SURGERY TO ATTEMPT TO ALLEVIATE THE PAIN.
Patient problems: Pain
MAUDE report 10944197 ↗MalfunctionSep 25, 2020Separation Problem; Separation Problem
ON (B)(6) 2020, A PATIENT UNDERWENT SPINAL PROCEDURE. ON (B)(6) 2020, RADIOGRAPHS INDICATE THE MASS REDUCTION SCREW DID NOT BREAK OFF CORRECTLY. AS PER REPORTER, IT HAS NOT BEEN DECIDED IF PATIENT WILL UNDERGO A REVISION PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10587130 ↗MalfunctionOct 15, 2018Migration or Expulsion of Device; Migration or Expulsion of Device
ON (B)(6) 2018 PATIENT UNDERWENT AN EXTREME LATERAL INTERBODY FUSION PROCEDURE WITH NO REPORTED ISSUES. ON (B)(6) 2018 PATIENT UNDERWENT A REVISION PROCEDURE DUE TO HARDWARE MALPOSITION. NO OTHER INFORMATION PROVIDED.
Patient problems: Failure of Implant
MAUDE report 7965968 ↗
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Elegance® Anterior Cervical Plate 53430353Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430108Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430114Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430240Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430236Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.