Skip to content

ICU Medical B99172Recalls & reported problems

Icu Medical, Inc. · 117" (297 cm) 60 Drop 24 Hour 150 ml Burette Set (Bravo24®, Shut-Off), Check Valve, 2 Bravo24®, Rotating Luer · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887709019225), received between Aug 27, 2025 and Aug 27, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “No Flow” (1 report).

188 other recalls cover devices cleared under the same FDA submission (K964435); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • No Flow1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 27, 2025No Flow; No Flow

    IT WAS REPORTED THAT A 117¿ (297 CM) 60 DROP 150 ML BURETTE SET (CLAVE¿, SHUT-OFF) W/2 CLAVE¿, ROTATING LUER WITH LIST NUMBER B99172 AND LOT NUMBER 14065212. IT WAS STATED IN THE REPORT THAT EARLIER THIS WEEK, DURING THE FIRST 100 CC OF FLUID ADMINISTRATION TO THE BABY, THE BLUE RING FLOATED AS EXPECTED. ONCE THE FIRST 100 CC WAS GIVEN TO THE PATIENT, THE ANESTHESIOLOGIST STARTED TO REFILL THE CHAMBER. ONCE THE CHAMBER WAS REFILLED, THEY OBSERVED THAT THE INTRAVENOUS (IV) WAS NOT FLOWING. WHILE TROUBLESHOOTING THAT PROBLEM, HE NOTICED THAT THE BLUE RING WAS STUCK TO THE BOTTOM OF THE BURETEROL CHAMBER, AND DESPITE THEIR EFFORTS, THE BLUE RING WOULD NOT FLOAT BACK UP AND WAS STUCK TO THE BASE OF THE CHAMBER. THAT WOULD NOT ALLOW THE FLUID TO FLOW FORWARD. THEY HAD TO TAKE THE SAID BURETEROL SET OUT OF THE SYSTEM, AND USED A SECOND BURETEROL, WHICH WORKED AS EXPECTED. THE FLUID WAS A LACTATED RINGER'S WITH PART NUMBER 07953-09, AND THERE WAS NO DRUG QUALITY ISSUE WITH THE LACTATED RINGER'S. THE SAMPLE IS AVAILABLE FOR EVALUATION. THERE WAS NO PATIENT HARM, BUT THERE WAS A COUPLE OF MINUTES' DELAY IN THERAPY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22906306 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K964435. One submission often covers many models, so check the product and lot details in each record.

  • Z-3163-2026 · May 12, 2026 · Open, Classified
    IV Sets with drip chambers
  • Z-3157-2026 · May 12, 2026 · Open, Classified
    IV Non-Dedicated Gravity Administration Sets with drip chambers
  • Z-0154-2026 · Oct 2, 2025 · Open, Classified
    IV Administration sets. 23" (58 cm) 150 mL Burette Set (Clave, Shut Off) w/Clave, Luer Lock, REF: B33359; 23" (58 cm) 150 ml Burette Set (w/Shut Off), MicroClave, Clamp, REF: B
  • Z-1721-2022 · Aug 1, 2022 · Open, Classified
    6.5" (17 cm) Appx 0.84 ml, Smallbore Bifuse Ext Set w/2 MicroClave Clear, 2 Check Valves, Luer Lock;
  • Z-0957-2021 · Dec 2, 2020 · Terminated
    7 IN (18cm) APPX 0.43ml, SMALLBORE SET, MicroCLAVE, FILTER SetSource - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which pro
  • Z-0955-2021 · Dec 2, 2020 · Terminated
    60 IN (152cm) APPX 1.5 ml, PUR YELLOW SMALLBORE SET, FILTER REF B2209 - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which pr
  • Z-0958-2021 · Dec 2, 2020 · Terminated
    154 cm (61 IN) APPX 1.5ml, PUR YELLOW EXT, 1.2 MICRON FILTER - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which provides ac
  • Z-0956-2021 · Dec 2, 2020 · Terminated
    60" (152 cm) Appx 1.9 ml, Smallbore Ext Set w/MicroClave Clear, 1.2 Micron Filter, 2 Clamps, Luer Lock REF MC330174 - Product Usage: The intravascular administration set is a singl
  • Z-0207-2021 · Jul 6, 2020 · Terminated
    13 IN(33cm) APPX 1.0 ml, SMALLBORE SET, 4 MicroClave Clear, NanoClave T-Conn, Filter; 1 unit per pouch, 50 pouches per case. UDI:(01)10887709085210(17)250101(30)50(10)4572801; (01)
  • Z-0234-2021 · Jul 6, 2020 · Terminated
    47 IN (119cm) APPX 6.7 ml, EXT, STOPCOCK, 3-Port NanoClave MANIFOLD, MicroClave Clear. 1 unit per pouch, 25 pouches per case. UDI:(01)10887709121154(17)250101(30)25(10)4556714; (01
  • Z-0245-2021 · Jul 6, 2020 · Terminated
    126 IN (320cm) APPX 23.5ml, 10 Drop Set 3 Clave, Remv Clave Stopcock, 2 Ext.1 unit per pouch, 25 pouches per case. UDI:(01)10887709062365(17)250201(30)25(10)4630752. The Intrav
  • Z-0214-2021 · Jul 6, 2020 · Terminated
    99 IN (251cm) APPX 12.6ml, 20 Drop, 2 Clave, 2 NanoClave 4-Way Stopcocks, Drop-In Ext, Clave; 1 unit per pouch, 25 pouches per case. UDI: (01)10887709066318(17)241201(30)25(10)4515
  • Z-0210-2021 · Jul 6, 2020 · Terminated
    13 IN (33cm) APPX 0.96 ml, PENTAFUSE SMALLBORE SET, NanoClave, 3 MicroClave Clear. 1 unit per pouch, 50 pouches per case. UDI:(01)10887709090245(17)250101(30)50(10)4557533; (01)108
  • Z-0185-2021 · Jul 6, 2020 · Terminated
    5 IN(13cm) APPX 0.87ml, EXT SET,NanoClave T-CONNECTOR; 1 unit per pouch, 50 pouches per case; UDI: (01)10887709052809(17)250101(30)50(10)4599980.
  • Z-0216-2021 · Jul 6, 2020 · Terminated
    54 IN (137 cm) APPX 7.2 ml EXT SET w NanoClave 4-Way Stopcock ;UDI:(01)10840619082526(17)250201(30)50(10)4718579. The Intravascular Administration Set is a single use, sterile, n

…and 173 more.

Other Stopcock, i.V. Set devices

All Stopcock, i.V. Set devices →

Sources and updates