ICU Medical MC33717Recalls & reported problems
Icu Medical, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887709064829), received between Feb 7, 2025 and Mar 26, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
188 other recalls cover devices cleared under the same FDA submission (K964435); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Fluid/Blood Leak2
- Material Separation1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 26, 2025Break; Fluid/Blood Leak; Material Separation; Break; Fluid/Blood Leak; Material Separation
THE EVENT INVOLVED A 7.5" (19 CM) APPX 1.2 ML, BIFUSE EXT SET W/2 MICROCLAVE® CLEAR, 3 CLAMPS (2 WHITE, BLUE), LUER LOCK WHERE THE CUSTOMER REPORTED THAT THEY HAVE HAD INCIDENT REPORTS OF BIFUSE BREAKING OFF FROM THE LUER CONNECTION. ALL THE BREAKS REPORTEDLY HAPPENED WHERE THE MALE LUER LOCK INSERTS INTO THE PATIENT¿S MICROCLAVE CAP. THE CUSTOMER STATED THAT THIS RESULTED IN BLOOD LOSS AND IVF LOSS FOR THE PATIENTS, AND CHEMO SPILLS. THE CUSTOMER STATED THAT THERE WERE MANY INCIDENCES OF BROKEN EQUIPMENT BUT THEY ARE UNABLE TO GIVE ACCURATE INFORMATION ABOUT WHICH BROKEN EXTENSION TUBING (BI/TRI/QUAD FUSE) HAD HARM; THE CUSTOMER FURTHER STATED THAT MOST DID HAVE SOME HARM IN BLOOD LOSS BUT THE VOLUME OF BLOOD LOSS WAS NOT ABLE TO BE OBTAINED. THE CUSTOMER STATED THAT THE MAJORITY OF THE BLOOD LOSS WAS NOT SUBSTANTIAL ENOUGH TO REQUIRE BLOOD TRANSFUSION. THERE MAY HAVE BEEN SOME CHEMO EXPOSURE, BUT NONE REQUIRED EMERGENT CARE OR TREATMENT. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, A FOLLOW UP REPORT WILL BE SUBMITTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21699173 ↗MalfunctionFeb 7, 2025Break; Fluid/Blood Leak; Break; Fluid/Blood Leak
A COMPLAINT WAS RECEIVED WITH REGARDS TO 7.5" (19 CM) APPX 1.1 ML, BIFUSE EXT SET W/2 MICROCLAVE¿ CLEAR, 3 CLAMPS (2 WHITE, BLUE), LUER LOCK THAT EXPERIENCED BREAKAGE AND LEAKAGE. THE REPORTER STATED THAT "ALL THE BREAKS HAPPENED WHERE THE MALE LUER LOCK INSERTS INTO THE PATIENT¿S MICROCLAVE CAP. THEY THINK IT MAY BE A BONDING ISSUE. THIS RESULTED IN BLOOD LOSS AND IVF LOSS FOR THE PATIENTS, CHEMO SPILLS, AND CAN POTENTIALLY CAUSE GREAT HARM FOR THE PATIENTS." "PATIENTS DID NOT SUFFER HARM AS THESE WERE FOUND QUICKLY, BUT THE PATIENT¿S DID LOSE BLOOD AND CHEMO WAS ALSO SPILLED".
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 21339717 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K964435. One submission often covers many models, so check the product and lot details in each record.
- Z-3163-2026 · May 12, 2026 · Open, ClassifiedIV Sets with drip chambers
- Z-3157-2026 · May 12, 2026 · Open, ClassifiedIV Non-Dedicated Gravity Administration Sets with drip chambers
- Z-0154-2026 · Oct 2, 2025 · Open, ClassifiedIV Administration sets. 23" (58 cm) 150 mL Burette Set (Clave, Shut Off) w/Clave, Luer Lock, REF: B33359; 23" (58 cm) 150 ml Burette Set (w/Shut Off), MicroClave, Clamp, REF: B
- Z-1721-2022 · Aug 1, 2022 · Open, Classified6.5" (17 cm) Appx 0.84 ml, Smallbore Bifuse Ext Set w/2 MicroClave Clear, 2 Check Valves, Luer Lock;
- Z-0957-2021 · Dec 2, 2020 · Terminated7 IN (18cm) APPX 0.43ml, SMALLBORE SET, MicroCLAVE, FILTER SetSource - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which pro
- Z-0956-2021 · Dec 2, 2020 · Terminated60" (152 cm) Appx 1.9 ml, Smallbore Ext Set w/MicroClave Clear, 1.2 Micron Filter, 2 Clamps, Luer Lock REF MC330174 - Product Usage: The intravascular administration set is a singl
- Z-0958-2021 · Dec 2, 2020 · Terminated154 cm (61 IN) APPX 1.5ml, PUR YELLOW EXT, 1.2 MICRON FILTER - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which provides ac
- Z-0955-2021 · Dec 2, 2020 · Terminated60 IN (152cm) APPX 1.5 ml, PUR YELLOW SMALLBORE SET, FILTER REF B2209 - Product Usage: The intravascular administration set is a single use, sterile, non pyrogenic device, which pr
- Z-0214-2021 · Jul 6, 2020 · Terminated99 IN (251cm) APPX 12.6ml, 20 Drop, 2 Clave, 2 NanoClave 4-Way Stopcocks, Drop-In Ext, Clave; 1 unit per pouch, 25 pouches per case. UDI: (01)10887709066318(17)241201(30)25(10)4515
- Z-0203-2021 · Jul 6, 2020 · Terminated8.5" (22 cm) Appx 0.57 ml, Smallbore Ext Set w/NanoClave, 0.2 Micron Filter, Clamp, Rotating Luer;1 unit per pouch, 50 multivac pouches per case.UDI:(01)10887709077671(17)250101(30
- Z-0233-2021 · Jul 6, 2020 · Terminated139" (353 cm) 15 Drop Admin Set w/3 MicroClave Clear, 4-Way Stopcock, 3-Port NanoClave Manifold w/Check Valve, Spin Luer, 2 Ext. 1 unit per pouch, 25 pouches per case. UDI:(01)1088
- Z-0186-2021 · Jul 6, 2020 · Terminated7" (18 cm) Appx 0.29 ml, Smallbore Ext Set w/MicroClave Clear, NanoClave, Clamp, Rotating Luer; 1 unit per pouch, 50 multivac pouches per case. UDI:(01)10887709051048(17)250101(30)
- Z-0191-2021 · Jul 6, 2020 · Terminated5" (13 cm) Appx 0.39 ml, Smallbore Bifuse Ext Set w/NanoClave T-Connector, 2 Clamps, Rotating Luer; 1 unit per pouch, 50 multivac pouches per case. UDI:(01)10887709053028(17)250101
- Z-0236-2021 · Jul 6, 2020 · Terminated7 IN (18cm) APPX 1.2ml Ext Set w/6-Port NanoClave Manifold, Check Valve. 1 unit per pouch, 50 pouches per case. UDI:(01)10887709067582(17)241201(30)50(10)4548270; (01)1088770906
- Z-0194-2021 · Jul 6, 2020 · Terminated7" (18 cm) Appx 0.25 ml, Smallbore Ext Set w/Remv NanoClave, Clamp, Luer Lock. 1 unit per pouch, 50 multivac pouches per case. UDI: (01)10887709065069(17)250101(30)50(10)4590843;(0
…and 173 more.
Other Stopcock, i.V. Set devices
- Connecta, Luer-Lok 394910BD Switzerland Sàrl · Stopcock, i.V. Set3 recalls8 reports
- Outlook® 490361B. Braun Medical Inc. · Stopcock, i.V. Set3 recalls0 reports
- Blood Administration Set 490530B. Braun Medical Inc. · Stopcock, i.V. Set2 recalls11 reports
- Medex MX9341LIcu Medical, Inc. · Stopcock, i.V. Set63 reports
- ICU Medical AC135Icu Medical, Inc. · Stopcock, i.V. Set1 recall10 reports
- IV Administration Set 490067B. Braun Medical Inc. · Stopcock, i.V. Set1 recall9 reports
- ICU Medical MC330174Icu Medical, Inc. · Stopcock, i.V. Set1 recall4 reports
- ICU Medical Z2587Icu Medical, Inc. · Stopcock, i.V. Set1 recall3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page