LOCKING SCREW 1312-20-420Recalls & reported problems
Biomet Orthopedics, LLC · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887868013676), received between Jul 21, 2023 and Jul 21, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Migration or Expulsion of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Migration or Expulsion of Device1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 21, 2023Migration or Expulsion of Device; Migration or Expulsion of Device
IT WAS REPORTED THAT DURING A ROUTINE RADIOGRAPH, IT WAS FOUND THAT THE IMPLANTED PLATE WAS FRACTURED. THE PATIENT STATES THERE WAS NO FALL, INJURY, OR VIOLENCE WHICH WOULD HAVE CAUSED THIS FRACTURE. THE PATIENT WAS REVISED APPROXIMATELY 2 MONTHS POST IMPLANTATION. RADIOGRAPHIC REVIEW FURTHER DISCOVERED THAT THERE WAS PARTIAL WITHDRAWAL OF THE TRAPEZIUM SCREW IN ADDITION TO THE IMPLANT FRACTURE AND MALUNION. ATTEMPTS HAVE BEEN MADE AND THERE IS NO FURTHER INFORMATION AT THIS TIME.
Patient problems: Failure of Implant
MAUDE report 17372453 ↗
FDA clearance and classification
The FDA regulates product code JDW (pin, fixation, threaded) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the LOCKING SCREW 1312-20-420
Has the LOCKING SCREW 1312-20-420 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00887868013676), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the LOCKING SCREW 1312-20-420?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 21, 2023. That report lists device problem “Migration or Expulsion of Device” (1); patient problem “Failure of Implant” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the LOCKING SCREW 1312-20-420?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the LOCKING SCREW 1312-20-420, and is it still sold?
The FDA's device database lists Biomet Orthopedics, LLC as the company responsible for it (brand LOCKING SCREW, model 1312-20-420). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PIN, FIXATION, THREADED devices
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall2 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- APEX 5038-1-080Stryker GmbH · PIN, FIXATION, THREADED48 reports
- Agee Digit Widget® DWD-232Hand Biomechanics Lab Inc · Pin, Fixation, Threaded32 reports
- SPATIAL FRAME 71070720Smith & Nephew, Inc. · PIN, FIXATION, THREADED15 reports
- APEX 5038-2-110Stryker GmbH · PIN, FIXATION, THREADED11 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page