Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887868480256), received between Jan 23, 2023 and Aug 1, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
- Material Twisted/Bent1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 1, 2025Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT WHILE DRILLING FOR THE SCREW, THE DRILL GOT CAUGHT AND SPUN INSIDE THE CUP, WHICH BENT THE FLEXIBLE DRILL. THE TECH HAD ACCIDENTALLY HIT POWER RELEASE WHEN HANDING THE DRILL TO THE SURGEON. THERE WAS NO KNOWN IMPACT OR CONSEQUENCES TO THE PATIENT. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22693365 ↗MalfunctionJan 23, 2023Fracture; Fracture
IT WAS REPORTED DURING ROUTINE INSPECTION THAT THE FLEXIBLE DRILL SHAFT WAS BROKEN, AND SPRING WAS STICKING OUT. NO KNOWN IMPACT OR CONSEQUENCE TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16225165 ↗
Other Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented devices
- AcuMatch 142-32-27Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented2 recalls0 reports
- Novation 140-36-52Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall8 reports
- G7 DEPTH GAUGE 110010717Biomet Orthopedics, LLC · Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented54 reports
- Novation 140-32-52Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall2 reports
- Novation 142-32-61Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall1 report
- Novation 140-36-54Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall1 report
- Novation 142-32-51Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall0 reports
- Novation 142-40-64Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page