HVAD® Controller 1420 (UDI 00888707007658)Recalls & reported problems

Heartware Inc. · Class 3 · Implant

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This HeartWare HVAD controller runs an implanted heart assist pump. The 282 reports often describe power and battery problems, including controller alarms. The reports include no deaths and 11 injuries. There is 1 open recall, from March 2022, over translation errors in the controller displays and manuals. Reports fell to 38 in the last year from 98 in the year before.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
281
Deaths reported
0
Injuries reported
10
Recalls naming it
1

Summary

The FDA's MAUDE database contains 281 adverse event reports that list this exact device (DI 00888707007658), received between Apr 21, 2021 and Sep 30, 2026 — classified as 10 injuries, 271 malfunctions.

The most frequently reported specific device problem is “Power Problem” (133 reports).

1 FDA recall record name this device's identifier, 1 still open.

59 other recalls cover devices cleared under the same FDA submission (P100047); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 7 reportsFeb 2024: 5 reportsMar 2024: 4 reportsApr 2024: 13 reportsMay 2024: 9 reportsJun 2024: 14 reportsJul 2024: 9 reportsAug 2024: 4 reportsSep 2024: 9 reportsOct 2024: 3 reportsNov 2024: 8 reportsDec 2024: 3 reportsJan 2025: 9 reportsFeb 2025: 9 reportsMar 2025: 9 reportsApr 2025: 10 reportsMay 2025: 13 reportsJun 2025: 9 reportsJul 2025: 11 reportsAug 2025: 5 reportsSep 2025: 6 reportsOct 2025: 6 reportsNov 2025: 13 reportsDec 2025: 12 reportsJan 2026: 6 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 6 reportsOct 2026: 0 reports20242025202614
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Mar 30, 2022Open, Classified

    Finnish and Turkish translation errors in HVAD controller and monitor displays as will as Instructions for Use, Patient Manual, and Emergency Responder Guide for the HeartWare Ventricular Assist Device (HVAD) system.

    Z-1105-2022 · Root cause: Labeling design · FDA record ↗

Most reported problems

Device problems

  • Power Problem133
  • Battery Problem108
  • Use of Device Problem38
  • Electrical /Electronic Property Problem22
  • Connection Problem20
  • Material Twisted/Bent18
  • Disconnection17
  • Display or Visual Feedback Problem14

Patient problems

  • No Clinical Signs, Symptoms or Conditions273
  • Confusion/ Disorientation2
  • Dyspnea2
  • Fall2
  • Anxiety1
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Cyanosis1
  • Heart Failure/Congestive Heart Failure1

Recent adverse event reports

The 25 most recent of 281 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Battery Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50952780 ↗
  • MalfunctionSep 28, 2026Battery Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50923433 ↗
  • MalfunctionSep 23, 2026Power Problem

    Upon review of log file data it was identified that the controller exhibited controller loss of power. the Controller remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50870891 ↗
  • MalfunctionSep 16, 2026Electrical /Electronic Property Problem; Use of Device Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50793942 ↗
  • MalfunctionSep 8, 2026Electrical /Electronic Property Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50675385 ↗
  • MalfunctionSep 8, 2026Power Problem

    It was reported that review of log file data revealed a controller unexpected loss of power.  The controller remains in use.  No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50670478 ↗
  • MalfunctionJan 26, 2026Use of Device Problem; Battery Problem; Power Problem

    IT WAS REPORTED THAT A CONTROLLER FAULT ALARM OCCURRED DUE TO INTERNAL BATTERY DEPLETION. SUBSEQUENTLY, A DOUBLE POWER DISCONNECT EVENT OCCURRED DUE TO THE PATIENT MANIPULATION ERROR, CAUSING THE CONTROLLER FAULT ALARM TO SOUND AGAIN. THE CONTROLLER FAULT ALARM WAS PERMANENTLY MUTED AGAIN. THE CONTROLLER REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24179951 ↗
  • MalfunctionJan 22, 2026Use of Device Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A DOUBLE DISCONNECT OF POWER SOURCES, WHICH WAS ATTRIBUTED TO PATIENT CONFUSION. THE CONTROLLER REMAINS IN USE. NO PATIENT SYMPTOMS OR COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Confusion/ Disorientation

    MAUDE report 24148688 ↗
  • MalfunctionJan 22, 2026Use of Device Problem; Power Problem

    IT WAS REPORTED THAT A REVIEW OF LOG FILE DATA REVEALED THE CONTROLLER EXHIBITED AN UNEXPECTED LOSS OF POWER. THE CONTROLLER REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24147118 ↗
  • MalfunctionJan 15, 2026Battery Problem

    IT WAS REPORTED THAT A CONTROLLER FAULT ALARM DUE TO INTERNAL BATTERY END OF LIFE. THE ALARM WAS CONFIRMED, AND THE CONTROLLER WAS EXCHANGED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24083250 ↗
  • MalfunctionJan 13, 2026Data Problem

    IT WAS REPORTED THAT A DATA TRANSFER ERROR OCCURRED WHEN DOWNLOADING THE LOGFILES FROM THE CONTROLLER TO THE MONITOR. INSUFFICIENT OR INCOMPLETE LOG DATA WAS RECEIVED TO GENERATE A REPORT. THE CONTROLLER REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24055185 ↗
  • MalfunctionJan 5, 2026Battery Problem

    IT WAS REPORTED THAT A CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM WHICH WAS ATTRIBUTED TO A DEPLETED INTERNAL BATTERY. THE CONTROLLER FAULT ALARM WAS SUBSEQUENTLY SILENCED AND THE CONTROLLER REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23960694 ↗
  • MalfunctionDec 26, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED AN ALARM, SPECIFICALLY A CONTROLLER FAULT ALARM, DUE TO DEPLETION OF THE INTERNAL BATTERY. THE ISSUE WAS RESOLVED BY EXCHANGING THE CONTROLLER. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23896241 ↗
  • MalfunctionDec 23, 2025Use of Device Problem; Power Problem; Use of Device Problem; Power Problem

    IT WAS FURTHER REPORTED THAT THE LOSS OF POWER OCCURRED DUE TO A DOUBLE DISCONNECTION OF BOTH POWER SOURCES BY THE PATIENT. THE PATIENT WAS CONVERTING FROM WALL POWER TO BATTERY AND ACCIDENTALLY DISCONNECTED BOTH POWER SOURCES. NO ISSUE WITH PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23878196 ↗
  • MalfunctionDec 22, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM ATTRIBUTED TO A DEPLETED INTERNAL BATTERY. THE CONTROLLER WAS EXCHANGED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23864399 ↗
  • MalfunctionDec 18, 2025Electrical /Electronic Property Problem; Electrical /Electronic Property Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM. THE PATIENT REFUSED A CONTROLLER EXCHANGE SO THE SITE PERMANENTLY SILENCED THE CONTROLLER ALARM. THE CONTROLLER REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23839679 ↗
  • MalfunctionDec 16, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM DUE TO A DEPLETED INTERNAL BATTERY. THE CONTROLLER WAS EXCHANGED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23818792 ↗
  • MalfunctionDec 15, 2025Electrical /Electronic Property Problem; Electrical /Electronic Property Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED A CONTROLLER FAULT AT HOME AND PERFORMED A CONTROLLER EXCHANGE TO THE BACKUP CONTROLLER AT HOME. THE CONTROLLER WAS REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23805239 ↗
  • MalfunctionDec 11, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM DUE TO INTERNAL BATTERY DEPLETION. THE ALARM WAS PERMANENTLY SILENCED. AT THIS TIME, THE SITE IS NOT PLANNING TO PERFORM A CONTROLLER EXCHANGE. THE CONTROLLER REMAINS IN USE, AND NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23778605 ↗
  • MalfunctionDec 10, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM INDICATING A DEPLETED INTERNAL BATTERY. THE CONTROLLER WAS EXCHANGED WITH A NEW CONTROLLER. THE VENTRICULAR ASSIST DEVICE (VAD) REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23767908 ↗
  • MalfunctionDec 8, 2025Disconnection; Power Problem; Disconnection; Power Problem

    IT WAS FURTHER REPORTED THAT LOSS OF POWER EVENT OCCUR DUE TO A DOUBLE DISCONNECTION OF BOTH POWER SOURCES BY THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23751416 ↗
  • MalfunctionDec 4, 2025Battery Problem; Pumping Problem; Battery Problem; Pumping Problem

    IT WAS FURTHER REPORTED THAT THE CONTROLLER WAS EXCHANGED. REVIEW OF LOG FILES REVEALED A MOTOR START WITH PARAMETERS OUTSIDE OF THE TYPICAL RANGE ASSOCIATED WITH THE CONTROLLER EXCHANGE. THE VAD REMAINS IN USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23716301 ↗
  • MalfunctionDec 2, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM DUE TO AN INTERNAL BATTERY END OF LIFE. THE ALARM WAS CURRENTLY MUTED, AND THE CLINIC PLANNED TO DISCUSS AN EXCHANGE. THE CONTROLLER REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23696738 ↗
  • MalfunctionDec 1, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM, AND DEPLETION OF THE INTERNAL BATTERY. THE CONTROLLER FAULT ALARM WAS PERMANENTLY MUTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23681400 ↗
  • MalfunctionNov 20, 2025Battery Problem; Battery Problem

    IT WAS REPORTED THAT THE CONTROLLER EXHIBITED A CONTROLLER FAULT ALARM DUE TO DEPLETED INTERNAL BATTERY. THE CONTROLLER WAS INITIALLY SILENCED BUT WAS SUBSEQUENTLY EXCHANGED SEVERAL DAYS LATER. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23610269 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P100047. One submission often covers many models, so check the product and lot details in each record.

  • Z-0475-2024 · Oct 31, 2023 · Open, Classified
    HVAD (HeartWare Ventricular Assist Device) STERILE IMPLANT KIT, Model Number 1100
  • Z-1993-2023 · May 16, 2023 · Open, Classified
    HeartWare Ventricular Assist Device System. a) Monitor 1521US Explore Tech, b) Monitor 1521GB Explore Tech, c) Monitor 1521IL Explore Tech, d) Monitor 1521DE Explore Tech
  • Z-1512-2022 · Jun 28, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System Batteries, Product Number 1650DE
  • Z-1266-2022 · May 5, 2022 · Open, Classified
    HeartWare Battery, Model #1650DE, a component of the HeartWare Ventricular Assist Device (HVAD) System.
  • Z-1207-2022 · Apr 14, 2022 · Open, Classified
    HeartWare HVAD Pump Implant Kit, a) Model Number 1104JP, b) Model Number MCS1705PU
  • Z-1106-2022 · Mar 30, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System, Model Number 1521DE, MONITOR 1521DE EXPLORE TECH
  • Z-1104-2022 · Mar 30, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System Controller, Model Number 1420
  • Z-1102-2022 · Mar 30, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System, Pump Implant Kit, Model Number1104
  • Z-1103-2022 · Mar 30, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System Controller, Model Number 1407DE Kit
  • Z-1110-2022 · Mar 30, 2022 · Open, Classified
    Instructions for Use, Patient Manuals, and Emergency Responder Guides for HeartWare Ventricular Assist Device (HVAD) System. HVAD System. IFUs are distributed as part of the Pump
  • Z-1107-2022 · Mar 30, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System, individual pamphlets: HVAD System Emergency Responder Guide (FI-Finnish) HVAD System Emergency Responder Guide (FI-Finnish) H
  • Z-0726-2022 · Jan 27, 2022 · Open, Classified
    HeartWare Ventricular Assist Device (HVAD) System
  • Z-2478-2021 · Aug 6, 2021 · Open, Classified
    Medtronic HVAD Pump Implant Kits
  • Z-2191-2021 · Jun 3, 2021 · Open, Classified
    HeartWare HVAD Pump Implant Kit, REF 1153
  • Z-2188-2021 · Jun 3, 2021 · Open, Classified
    HeartWare HVAD Pump Implant Kit, REF 1103

…and 44 more.