Arthrex® AR-9503L-06Recalls & reported problems

Arthrex, Inc. · HUMERAL INSERT L/42 +6 TO FIT IN 42 CUP · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867061231), received between Nov 24, 2025 and Nov 24, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 24, 2025Positioning Failure; Positioning Failure

    ON 11/3/2025, IT WAS REPORTED VIA EMAIL BY A SALES REPRESENTATIVE THAT AN AR-9503L-06 ARTHREX UNIVERS REVERS HUMERAL INSERT LARGE WAS NOT SEATING PROPERLY IN A 42 NEUTRAL SUTURECUP. THE SURGEON NOTED THAT THE TAPER DID NOT APPEAR TO BE ENGAGING THE SUTURECUP CORRECTLY. AFTER FLUSHING BOTH THE SUTURECUP AND THE HUMERAL INSERT TO RULE OUT DEBRIS INTERFERENCE, THE ISSUE PERSISTED. THE SURGEON THEN OPENED A NEW UNIVERS REVERS HUMERAL INSERT, WHICH SEATED PROPERLY WITHOUT ISSUE. THIS WAS DISCOVERED DURING AN RTSA PROCEDURE ON (B)(6) 2025. ADDITIONAL INFORMATION WAS RECEIVED ON 11/11/2025: ON (B)(6) 2025, DURING AN RTSA PROCEDURE, THE SURGEON ENCOUNTERED AN ISSUE WITH SEATING AN AR-9503L-06 ARTHREX UNIVERS REVERS HUMERAL INSERT (LARGE) INTO AN AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP, 42 (NEUTRAL). THE TAPER ON THE INSERT DID NOT APPEAR TO ENGAGE PROPERLY WITH THE SUTURE CUP, AND THE TAPER WAS CONFIRMED TO BE PART OF THE INSERT. THIS OCCURRED DURING THE FINAL IMPLANTATION INSIDE THE PATIENT. NO COMPONENT FRACTURED INSIDE THE PATIENT. TO COMPLETE THE CASE, THE SURGEON ELECTED TO USE A SPACER AND A +3 POLYETHYLENE INSERT, SUSPECTING THE TAPER ON THE CUP MIGHT HAVE CONTRIBUTED TO TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23631091 ↗

Other shoulder prosthesis, reverse configuration devices

All shoulder prosthesis, reverse configuration devices →