Arthrex® AR-623-T812Recalls & reported problems
Arthrex, Inc. · IBAL TKA,TIB BEARING TRL SZ 8, 12MM · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867215405), received between Apr 18, 2024 and Apr 19, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 19, 2024Break; Break
ON (B)(6) 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS (B)(4) THAT AN AR-623-T812 IBALANCE TKA, TIBIAL BEARING TRIAL SIZE 8 WAS BROKEN DURING USE WITH NO FURTHER INFORMATION PROVIDED. THERE WAS NO EFFECTS TO THE PATIENT REPORTED. THIS WAS DISCOVERED DURING A PROCEDURE. ADDITIONAL INFORMATION WAS RECEIVED ON 3/29/2024: THE IMPACTOR WAS BROKEN WHEN THE TIBIAL IMPLANT WAS IMPLANTED; THE POLY TRIAL BROKE WHEN ATTEMPTING TO TRIAL THE SIZES. THE DEVICE BROKE WHILE BEING PUT INTO THE PATIENT, AND ALL FRAGMENTS WERE RETRIEVED FROM THE PATIENT. THE CASE WAS DELAYED BY ABOUT A MINUTE WHEN SWITCHING TO ANOTHER POLY TRIAL SIZE. THE CASE WAS COMPLETED WITH ANOTHER TRIAL AND FINISHED NORMALLY WITH NO ADVERSE EFFECTS ON THE PATIENT. THIS WAS DISCOVERED DURING A TOTAL KNEE ARTHROPLASTY PROCEDURE ON (B)(6) 2024.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19146753 ↗MalfunctionApr 18, 2024Break; Break
ON (B)(6) 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS (B)(4) THAT AN AR-623-36 I BALANCE TKA, TIBIAL IMPACTOR AND AN AR-623-T812 IBALANCE TKA, TIBIAL BEARING TRIAL SIZE 8 BROKE DURING USE WITH NO FURTHER INFORMATION PROVIDED. THIS WAS DISCOVERED DURING A PROCEDURE, WITH NO REPORTED PATIENT HARM. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19140549 ↗
Other TEMPLATE devices
- ATTUNE 2544-01-014Depuy (Ireland) · TEMPLATE802 reports
- ATTUNE 2545-00-546Depuy (Ireland) · TEMPLATE1 recall301 reports
- ARTICUL/EZE 2531-51-000Depuy (Ireland) · TEMPLATE323 reports
- DELTA XTEND 2307-95-000Depuy (Ireland) · TEMPLATE315 reports
- ATTUNE 2545-00-547Depuy (Ireland) · TEMPLATE1 recall231 reports
- ATTUNE 2544-00-520Depuy (Ireland) · TEMPLATE279 reports
- ATTUNE 2545-00-545Depuy (Ireland) · TEMPLATE1 recall221 reports
- ARTICUL/EZE 2530-91-000Depuy (Ireland) · TEMPLATE271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page