Arthrex® AR-523-B314Recalls & reported problems
Arthrex, Inc. · PS TIBIAL BEARING, SIZE 3, 14MM, VIT E · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867232402), received between Oct 21, 2019 and Oct 21, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Loose or Intermittent Connection1
- Unstable Capture Threshold1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 21, 2019Loose or Intermittent Connection; Unstable Capture Threshold
IT WAS REPORTED THAT A PATIENT HAD A TOTAL KNEE PROCEDURE ON (B)(6) 2018. ROUGHLY ONE AND A HALF YEARS AFTER IMPLANTATION THE AR-523-B314 (LOT: 115571546) TIBIAL BEARING CAME LOOSE FROM THE TIBIAL TRAY, AND THE KNEE BECAME UNSTABLE. THE FOLLOWING ARTHREX PARTS WERE USED DURING THE PRIMARY PROCEDURE: AR-523-B314 // LOT: 115571546 // QTY.: 1. AR-524-PSC9 // LOT: 132581730 // QTY.: 1. AR-513-T3 // LOT: 10167303 // QTY.: 1. AR-516-5R // LOT: 10183110 // QTY.: 1. A BEARING EXCHANGE PROCEDURE TOOK PLACE ON (B)(6) 2019. DURING THE REVISION PROCEDURE THE SURGEON EXPLANTED THE AR-523-B314 (LOT: 115571546), AND IMPLANTED AR-513-BD18 (LOT: 113601819). THE REP REPORTED THE POLY WAS THE ONLY ARTHREX DEVICE EXPLANTED DURING THE REVISION PROCEDURE. THE PRIMARY RIGHT TKA AND THE BEARING EXCHANGE PROCEDURE WERE PERFORMED BY THE SAME SURGEON. THE EXPLANTED DEVICE HAS BEEN RETURNED TO ARTHREX.
Patient problems: Failure of Implant
MAUDE report 9214786 ↗
Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices
- ATTUNE 1512-14-050Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER106 reports
- ATTUNE 1504-40-205Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall53 reports
- ATTUNE 1504-40-105Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall46 reports
- ATTUNE 1547-06-001Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall37 reports
- ATTUNE 1513-12-060Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER72 reports
- Triathlon 5521-B-300Howmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- Triathlon 5531-G-709-EHowmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- ATTUNE 1512-16-080Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page