Arthrex® AR-8964-04Recalls & reported problems

Arthrex, Inc. · 5.0mm Self Drill Schanz Screw, 200mm, SS · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867241138), received between Apr 22, 2026 and Apr 22, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem1

Patient problems

  • Loss of fracture reduction1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 22, 2026Patient Device Interaction Problem

    ON 01-APR-2026, A SALES REPRESENTATIVE REPORTED VIA EMAIL THAT SEVEN AR-8964-07 LARGE COMBINATION CLAMPS, FOUR AR-8964-27 STRAIGHT ATTACHMENT ARMS, TWO AR-8964-08 MULTI-PIN CLAMPS (LARGE), AND THREE AR-8964R-450 CARBON RODS (450 MM) WERE USED IN A KNEE-SPANNING EXTERNAL FIXATION CONSTRUCT WITH THE ARTHROFX EXTERNAL FIXATION SYSTEM DURING A SURGICAL PROCEDURE PERFORMED ON (B)(6) 2026. THE CONSTRUCT INCLUDED TWO 5 MM ARTHROFX SCHANZ PINS PLACED IN THE FEMUR AND TWO 5 MM ARTHROFX SCHANZ PINS PLACED IN THE TIBIA TO ADDRESS A PROXIMAL TIBIAL FRACTURE. INTRAOPERATIVELY, THE SURGEON APPLIED DISTRACTION, BROUGHT THE FRACTURE TO LENGTH, TIGHTENED ALL COMBINATION CLAMPS, AND COMPLETED THE PROCEDURE WITHOUT ISSUE. WITHIN APPROXIMATELY 36¿48 HOURS POSTOPERATIVELY, FOLLOW-UP X-RAY IMAGING DEMONSTRATED LOSS OF FRACTURE REDUCTION, AND THE EXTERNAL FIXATOR WAS NOTED TO HAVE SLIPPED. A REVISION SURGERY WAS SUBSEQUENTLY PERFORMED ON (B)(6) 2026. DURING THE REVISION, THE SURGEON INITIALLY ATTEMPTED TO REUSE THE EXISTING ARTHROFX 5 MM SCHANZ PINS; HOWEVER, WHEN DISTRACTION WAS APPLIED USING AN ALTERNATE MANUFACTURER¿S COMBINATION CLAMPS, INTRAOPERATIVE X-RAY IMAGING DEMONSTRATED BENDING OF THE ARTHROF

    Patient problems: Loss of fracture reduction

    MAUDE report 24952608 ↗