Arthrex® AR-9560-28-2Recalls & reported problems
Arthrex, Inc. · 28mm +2 LAT Baseplate, MODULAR · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867296503), received between Oct 10, 2022 and Apr 4, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated2
- Defective Device1
- Material Separation1
- Positioning Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 4, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
ON 10/11/2021, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA E-MAIL THAT WHILE THE SURGEON WAS USING AN AR-9622 TAPER ASSEMBLY PRESS WAS USED TO PAIR THE AR-9560-28-2, 28MM +2 LAT. MGS BASEPLATE AND AR-9561-35S, 35MM CENTRAL SCREW, BUT UPON INSERTION THE BASEPLATE AND CENTRAL SCREW DISASSOCIATED. THIS WAS DISCOVERED DURING A REVERSE TOTAL SHOULDER ARTHROPLASTY ON 10/5/2021. THE CASE WAS COMPLETED BY REMOVING THE CENTRAL SCREW FROM THE GLENOID WITH REMOVAL DRIVER AND THEN OPENED NEW IMPLANTS WITH NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19042471 ↗MalfunctionMar 20, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A UNIVERS REVERS SURGERY WITH A MODULAR GLENOID SYSTEM THE BASEPLATE AND CENTRAL SCREW WERE DISLOCATED DURING IMPLANTATION. THE BASEPLATE AND CENTRAL SCREW WERE ASSEMBLED CORRECTLY. THE BASEPLATE WAS SEATED CORRECTLY ON THE PRESS, THE CENTRAL SCREW WAS PLACED CORRECTLY (PLACED, ROTATED UNTIL THE HEX PIN ENGAGES AND THERE IS NO LONGER A VISIBLE GAP BETWEEN THE BASEPLATE AND CENTRAL SCREW) AND TIGHTENED CORRECTLY UNTIL THE DISPLAY SHOWS BETWEEN THE MIN AND MAX MARKINGS. WHEN IMPLANTING THE BASEPLATE AND CENTRAL SCREW, THE BASEPLATE COULD NOT BE SCREWED IN SUFFICIENTLY DUE TO HARD BONE SO THAT THE BACK OF THE BASEPLATE LAID ON THE GLENOID WITH SATISFACTORY COMPRESSION. THE SURGEON THEN TRIED TO TIGHTEN THE BASEPLATE FURTHER USING THE BASEPLATE EXTRACTOR AND BASEPLATE EXTRACTOR WRENCH, BUT THE BASEPLATE BECAME DETACHED FROM THE CENTRAL SCREW. THE CENTRAL SCREW REMAINED IN THE GLENOID AND COULD BE REMOVED BY USING A 4MM HEX DRIVER. THE THREAD WAS THEN RECUT WITH THE THREAD CUTTER AND A NEW BASEPLATE WITH A NEW CENTRAL SCREW WAS INSERTED. THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY. THE SURGERY WAS FINISHED SUCCESSFULLY. IT WAS NOT NECESSARY TO SWIT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18944662 ↗MalfunctionOct 10, 2022Material Separation; Defective Device; Positioning Problem; Defective Device
IT WAS REPORTED ON 09/22/2022 BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-9560-28-2 BASEPLATE AND AR-9561-25S MODULAR SCREW WOULD NOT COMPRESS TOGETHER WITH THE MORSE TAPER USING THE TAPER ASSEMBLY PRESS. THIS WAS DISCOVERED DURING A CASE WITH NO PATIENT HARM. PER FACILITY: " IT WAS CONFIRMED THAT THE COMPRESSION LINE BETWEEN MAXIMUM AND MINIMUM WAS ACHIEVED BUT UP INSERTING THE IMPLANT THE TWO PIECES BECAME DISASSEMBLED. WE WERE ABLE TO RETRIEVE BOTH PARTS SAFELY WITHOUT HARMING THE PATIENT. WE THEN ASSEMBLED TWO NEW PARTS, SAME SIZES, AND IN THE SAME FASHION WITHOUT ISSUES."
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; No Clinical Signs, Symptoms or Conditions
MAUDE report 15571772 ↗
Other shoulder prosthesis, reverse configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page