Skip to content

DJO SURGICAL 508-00-004Recalls & reported problems

Encore Medical, L.P. · SOCKET, SHELL +4MM RSP HUMERAL · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888912024624), received between Mar 24, 2016 and Apr 2, 2024 — classified as 3 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

4 other recalls cover devices cleared under the same FDA submission (K041066); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Appropriate Device Problem Term/Code Not Available1
  • Device Dislodged or Dislocated1
  • Unstable1

Patient problems

  • Implant Pain1
  • Joint Dislocation1
  • Joint Laxity1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO PAIN AND LOOSENING.

    Patient problems: Implant Pain; Joint Laxity

    MAUDE report 19029790 ↗
  • InjuryApr 3, 2019Unstable; Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY - DUE TO THE PATIENT HAVING INSTABILITY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8480333 ↗
  • InjuryMar 24, 2016Device Dislodged or Dislocated

    REVISION SURGERY - DUE TO THE PATIENT HAVING DISLOCATED.

    Patient problems: Joint Dislocation

    MAUDE report 5523531 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K041066. One submission often covers many models, so check the product and lot details in each record.

  • Z-0098-2024 · Aug 22, 2023 · Open, Classified
    REVERSE PROSTHESIS SHOULDER SYSTEM, SCREW, LOCKING BONE, RSP, 5mmX30mm long, REF: 506-03-130
  • Z-0184-2008 · Aug 8, 2007 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP) System, Standard Size 36 RSP Humeral Socket Insert; Catalog #: 508-00-036; Sterile; Manufactured by Encore, Medical, L.P., Austin, TX 7875
  • Z-0185-2008 · Aug 8, 2007 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP) System, Standard Size 40 RSP Humeral Socket Insert; Catalog #: 508-00-040; Sterile; Manufactured by Encore, Medical, L.P., Austin, TX 7875
  • Z-1566-05 · Jul 28, 2005 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP), manufactured and distributed by Encore Medical, L.P. 9800 Metric Blvd., Austin, Texas 78758

Other shoulder prosthesis, reverse configuration devices

All shoulder prosthesis, reverse configuration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page