DJO SURGICAL 425-98-006Recalls & reported problems
Encore Medical, L.P. · Linear, STD, Reduced Neck, Sz 6, W/P2 Coating · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00888912078788), received between Jul 26, 2017 and Jan 10, 2025 — classified as 5 injuries.
The most frequently reported specific device problem is “Unstable” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K120241); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Unstable2
- Adverse Event Without Identified Device or Use Problem1
- Device Dislodged or Dislocated1
- Fracture1
Patient problems
- No Code Available3
- Failure of Implant2
- Bone Fracture(s)1
- Joint Dislocation1
- Joint Laxity1
- Loss of Range of Motion1
- Pain1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryJan 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION SURGERY - DUE TO SUBSIDENCE AND FRACTURE.
Patient problems: Bone Fracture(s); Joint Laxity
MAUDE report 21132043 ↗InjuryMay 8, 2019Unstable
REVISION SURGERY - DUE TO THE PATIENT BEING UNSTABLE, PAINFUL, LOSS OF MOTION.
Patient problems: Loss of Range of Motion; Pain
MAUDE report 8591350 ↗InjuryJan 2, 2019Unstable
REVISION SURGERY - THE PATIENT AND DOCTOR FOUND THE PRIMARY STEM'S STABILITY TO BE NOT TO THE PATIENTS LIKING AND IT WAS DECIDED TO REMOVE THE STEM AND REPLACE IT WITH AN EXPERT REVISION HIP STEM.
Patient problems: No Code Available
MAUDE report 8210598 ↗InjuryApr 10, 2018Fracture
REVISION SURGERY - DUE TO THE PATIENT FRACTURING AROUND THE FEMORAL PROSTHESIS A FEW DAYS AFTER PRIMARY TOTAL HIP ARTHROPLASTY. THE SURGEON REMOVED THE ORIGINAL STEM AND A REVISION PROSTHESIS WAS IMPLANTED WITH CABLES TO SECURE FRACTURE.
Patient problems: Failure of Implant; No Code Available
MAUDE report 7412843 ↗InjuryJul 26, 2017Device Dislodged or Dislocated
REVISION SURGERY - DUE TO THE PATIENT DISLOCATING IN POST OP.
Patient problems: Failure of Implant; Joint Dislocation; No Code Available
MAUDE report 6744643 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K120241. One submission often covers many models, so check the product and lot details in each record.
- Z-1692-2020 · Jul 10, 2018 · Open, Classifieddjosurgical Linear Neck Trials with Spring Sides, Standard, nonsterile, REF S-200635; and djosurgical Linear Neck Trials with Spring Sides, Lateral, nonsterile, REF S-200636. The
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page