DJO SURGICAL 391-15-705Recalls & reported problems
Encore Medical, L.P. · INSERT, 3D EX SZ 5LT 15MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888912119740), received between Jun 16, 2017 and Jan 27, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Unstable” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K091956); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Unstable1
Patient problems
- Failure of Implant1
- Joint Laxity1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 27, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
InjuryJun 16, 2017Unstable
REVISION SURGERY - POLY SWAP DONE FOR INSTABILITY.
Patient problems: Failure of Implant
MAUDE report 6648566 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K091956. One submission often covers many models, so check the product and lot details in each record.
- Z-2658-2017 · May 31, 2017 · Terminated3DKNEE(TM) SYSTEM e+, tibial Insert, LEFT Sz 6 / 11mm, REF 391-11-706, QTY 01, The 3DKnee Insert HXL Tibial Inserts are manufactured from ultra high molecular weight polyethylene
- Z-2659-2017 · May 31, 2017 · Terminated3DKNEE(TM) SYSTEM e+, Tibial Insert, RIGHT Sz 8 / 11mm, REF 391-11-708, QTY 01 The 3DKnee Insert HXL Tibial Inserts are manufactured from ultra high molecular weight polyethylene
- Z-1213-2013 · Apr 1, 2013 · Terminated3DKnee e+ Tibial Insert. The insert is used along with the other components that comprise the 3DKnee System.
- Z-2302-2012 · Aug 9, 2012 · Terminated3DKnee e+ Tibial Insert - HXLPE-VE, Sterile, Material: Highly cross linked vitamin E PE, Sz 2/9mm. The insert is intended to more closely match the kinematics of the knee, allowin
Other Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive devices
- iTotal® PS TPS111111102Conformis, Inc. · Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive327 reports
- ATTUNE 1506-00-006Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive287 reports
- ATTUNE 1506-00-008Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive233 reports
- iTotal® Cruciate Retaining (CR) Knee Replacement System TCR121111102Conformis, Inc. · Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive150 reports
- ATTUNE 1506-70-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive1 recall2 deaths74 reports
- ATTUNE 1516-40-506Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive121 reports
- ATTUNE 1506-70-006Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive1 recall70 reports
- ATTUNE 1516-40-605Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive120 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page