DJO SURGICAL 507-06-175Recalls & reported problems

Encore Medical, L.P. · STEM, HUMERAL, LONG, REVISION, RSP, SIZE6 · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00888912144070), received between Mar 4, 2016 and Sep 26, 2023 — classified as 6 injuries.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (2 reports).

4 other recalls cover devices cleared under the same FDA submission (K041066); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Loose or Intermittent Connection2
  • Device Dislodged or Dislocated1
  • Device Slipped1

Patient problems

  • Bone Fracture(s)1
  • Failure of Implant1
  • Fall1
  • Joint Laxity1
  • No Known Impact Or Consequence To Patient1
  • Unspecified Infection1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjurySep 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO FRACTURE.

    Patient problems: Bone Fracture(s)

    MAUDE report 17822431 ↗
  • InjuryJul 5, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 17262707 ↗
  • InjuryApr 11, 2019Loose or Intermittent Connection

    SECOND REVISION SURGERY - DUE TO A LOOSE HUMERAL COMPONENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8505664 ↗
  • InjuryJun 22, 2018Device Slipped

    REVISION SURGERY - DUE TO THE STEM LOOSENING.

    Patient problems: Failure of Implant

    MAUDE report 7630419 ↗
  • InjuryDec 19, 2017Adverse Event Without Identified Device or Use Problem

    THIRD REVISION SURGERY - DUE TO THE PATIENT DEVELOPING AN INFECTION. AN ANTIBIOTIC SPACER WAS IMPLANTED THEN REMOVED.

    Patient problems: Unspecified Infection

    MAUDE report 7129631 ↗
  • InjuryMar 4, 2016Loose or Intermittent Connection; Device Dislodged or Dislocated

    REVISION SURGERY - PATIENT WENT TO E.R. AFTER A FALL. ON THE X-RAY, THE STEM LOOKED DISLOCATED BUT THE SURGEON WAS UNABLE TO TELL ORIENTATION OF THE PLASTIC CUP ON THE X-RAY. THE SURGEON ATTEMPTED CLOSED REDUCTION WHICH WAS UNSUCCESSFUL. OPEN REDUCTION REVEALED THE TRAUMA OF THE FALL HAD LOOSENED THE STEM.

    Patient problems: Fall

    MAUDE report 5480994 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K041066. One submission often covers many models, so check the product and lot details in each record.

  • Z-0098-2024 · Aug 22, 2023 · Open, Classified
    REVERSE PROSTHESIS SHOULDER SYSTEM, SCREW, LOCKING BONE, RSP, 5mmX30mm long, REF: 506-03-130
  • Z-0185-2008 · Aug 8, 2007 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP) System, Standard Size 40 RSP Humeral Socket Insert; Catalog #: 508-00-040; Sterile; Manufactured by Encore, Medical, L.P., Austin, TX 7875
  • Z-0184-2008 · Aug 8, 2007 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP) System, Standard Size 36 RSP Humeral Socket Insert; Catalog #: 508-00-036; Sterile; Manufactured by Encore, Medical, L.P., Austin, TX 7875
  • Z-1566-05 · Jul 28, 2005 · Terminated
    Encore Reverse Shoulder Prosthesis (RSP), manufactured and distributed by Encore Medical, L.P. 9800 Metric Blvd., Austin, Texas 78758

Other shoulder prosthesis, reverse configuration devices

All shoulder prosthesis, reverse configuration devices →