Skip to content

mityhook 10035Recalls & reported problems

Coopersurgical, Inc. · mityhook amniotome - a sterile amniotome to rupture the amniotic membrane · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888937014761), received between Oct 30, 2024 and Jun 2, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Use of Device Problem1

Patient problems

  • Genital Bleeding1
  • Laceration(s)1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 2, 2025Use of Device Problem; Use of Device Problem

    IT WAS REPORTED BY HEALTH CANADA, THAT DURING THE BIRTH, THE DOCTOR HAD DIFFICULTY HOOKING THE MEMBRANES IN ORDER TO RUPTURE THEM. COMPLAINT IS THAT THE TOOL IS POORLY DESIGNED AND PROVIDES LITTLE TACTILE FEEDBACK. THIS RESULTED IN INJURIES TO THE PATIENT RESULTING IN VAGINAL BLEEDING. 1216677-2025-00033 (B)(6) MITYHOOK (B)(4).

    Patient problems: Genital Bleeding

    MAUDE report 22125982 ↗
  • InjuryOct 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO ADDITIONAL INFORMATION.

    Patient problems: Laceration(s)

    MAUDE report 20566318 ↗

FDA clearance and classification

The FDA regulates product code HGE (amniotome) under 21 CFR 884.4530 as a Class I device. 21 CFR 884.4530 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Common questions about the mityhook 10035

Has the mityhook 10035 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00888937014761), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the mityhook 10035?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Oct 30, 2024 and Jun 2, 2025. In those reports, the most common specific device problem is “Use of Device Problem” (1); the most common patient problems are “Genital Bleeding” (1) and “Laceration(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the mityhook 10035?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the mityhook 10035 FDA approved?

Devices of this type (product code HGE) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Coopersurgical, Inc.

Who makes the mityhook 10035, and is it still sold?

The FDA's device database lists Coopersurgical, Inc. as the company responsible for it (brand mityhook, model 10035). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page