Skip to content

Kinectiv® 00-7848-044-00Recalls & reported problems

Zimmer, Inc. · Class 2 · Implant

All models of Kinectiv (21)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024138049), received between Oct 18, 2023 and Oct 18, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

4 other recalls cover devices cleared under the same FDA submission (K063251, K182678); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem1

Patient problems

  • Joint Impingement1
  • Metal Related Pathology1
  • Pain1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 18, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED A PATIENT UNDERWENT A HIP REVISION APPROXIMATELY FIVE YEARS POST IMPLANTATION DUE TO PAIN AND A DISLOCATION. DURING THE REVISION, IT WAS NOTED THAT THE LINER AND RING WERE INTACT AND THAT THERE WAS SIGNIFICANT METAL DEBRIS (BLACK TISSUE) FOUND IN THE WOUND SITE. UPON EXAMINATION OF THE ANTERIOR NECK, IT WAS DISCOVERED THAT THIS ITEM WAS GRINDING ON THE ACETABULAR CUP. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Joint Impingement; Metal Related Pathology; Pain

    MAUDE report 17957839 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K063251, K182678. One submission often covers many models, so check the product and lot details in each record.

  • Z-2364-2018 · May 30, 2018 · Terminated
    Zimmer M/L Taper Hip Prosthesis With Kinectiv Technology Cementless, Size 6; 00-7713-006-00
  • Z-2375-2018 · May 30, 2018 · Terminated
    Zimmer M/L Taper Hip Prosthesis With Kinective Technology Cementless, Size 9; 00-7713-009-00
  • Z-2365-2018 · May 30, 2018 · Terminated
    Zimmer M/L Taper Hip Prosthesis With Kinective Technology Cementless, Size 10; 00-7713-010-00
  • Z-1617-2009 · May 29, 2009 · Terminated
    Zimmer Kinectivo Technology Modular Neck, BB, 12/14 neck taper, sterile, Zimmer, Warsaw, IN; Catalog Number: 00-7848-022-01. Orthopedic implant used in total hip arthroplasty.

Other PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices

All PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page