Continuum® Trabecular Metal™ 00-8757-054-01Recalls & reported problems
Zimmer, Inc. · Class 2 · Implant
All models of Continuum Trabecular Metal (17)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00889024151406), received between Nov 19, 2020 and Mar 16, 2026 — classified as 3 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Positioning Failure” (2 reports).
4 other recalls cover devices cleared under the same FDA submission (K091508, K151448, K200823); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Positioning Failure2
- Insufficient Device Problem Information1
- Migration1
- Naturally Worn1
- Osseointegration Problem1
- Unstable1
Patient problems
- Pain3
- No Clinical Signs, Symptoms or Conditions2
- Failure of Implant1
- Inadequate Osseointegration1
- Inflammation1
- No Information1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 16, 2026Positioning Failure
IT WAS REPORTED THAT THE ACETABULAR SCREW COULD NOT BE FULLY INSERTED DURING IMPLANTATION. REPEATED TAPPING ATTEMPTS STILL FAILED TO SECURE IT. UPON REMOVAL, THREAD SCRATCHES WERE OBSERVED, ALONG WITH A DOUBLE THREAD AT THE TIP. REPLACING IT WITH A SCREW OF THE SAME SPECIFICATION AND BATCH NUMBER RESULTED IN SUCCESSFUL IMPLANTATION. 30 MINS DELAY. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24604104 ↗InjuryOct 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MalfunctionJun 11, 2024Positioning Failure; Positioning Failure
IT WAS REPORTED THAT DURING THE SURGERY THE SCREW PENETRATED THE HOLE IN THE CUP. THE SCREW COULD NOT BE REMOVED AND WAS LEFT IN PLACE AT THE SURGEON'S DISCRETION. THE CUP HAD TO BE FIXATED WITH A SECOND SCREWED. THERE WAS NO KNOWN IMPACT OR CONSEQUENCESTO THE PATIENT. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19510392 ↗InjuryOct 4, 2023Naturally Worn; Adverse Event Without Identified Device or Use Problem; Naturally Worn; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A PATIENT UNDERWENT A HIP REVISION APPROXIMATELY NINE YEARS POST IMPLANTATION DUE TO PAIN AND A PSEUDOTUMOR. DURING THE PROCEDURE, INFLAMMATION AND IMPLANT WEAR WERE NOTED. THE SHELL WAS WELL FIXED AND REMAINS IMPLANTED. THE STEM, LINER, AND HEAD WERE REMOVED AND REPLACED.
Patient problems: Inflammation; Pain
MAUDE report 17868203 ↗InjuryNov 19, 2020Unstable; Adverse Event Without Identified Device or Use Problem; Osseointegration Problem; Insufficient Device Problem Information; Migration; Unstable; Adverse Event Without Identified Device or Use Problem; Osseointegration Problem; Insufficient Device Problem Information; Migration
IT WAS REPORTED THAT PATIENT UNDERWENT RIGHT TOTAL HIP ARTHROPLASTY AND WAS SUBSEQUENTLY REVISED 10 YEARS LATER DUE TO PAIN, INSTABILITY, CUP MIGRATION, LINER WEAR, AND METAL RELATED PATHOLOGY. OPERATIVE NOTE REPORTED INSTABILITY DUE TO POLY LINER DAMAGE WITH VERTICALLY ORIENTATED ACETABULAR COMPONENT. METALLOSIS 2ND TRUNNION WEAR MODULAR NECK AND STEM INTERFACE. TISSUE STAINED WITH GROSS GREYISH BLACK METALLOSIS TYPE TISSUE ON BOTH ACETABULAR AND FEMORAL COMPONENTS. CUP. LINER, HEAD AND STEM REVISED. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE.
Patient problems: Failure of Implant; Inadequate Osseointegration; No Information; Pain
MAUDE report 10869478 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K091508, K151448, K200823. One submission often covers many models, so check the product and lot details in each record.
- Z-2519-2023 · Jul 26, 2023 · Open, ClassifiedM/L Taper Hip Prosthesis Extended Offset, Reduced Neck Length, Size 4 (Item Number 00771100640) and Size 6 (Item Number 00771100440)
- Z-0094-2015 · Oct 1, 2014 · TerminatedContinuum Acetabular System Trabecular Metal Shell with Multi Holes, Porous 68mm, Prosthesis, Hip, Semi-Constrained, Metal/Polymer
- Z-0071-2011 · Mar 19, 2010 · TerminatedContinuum Acetabular Systems Shell Inserter Adapter with Rotational Control, 00-8790-003-00, Zimmer Inc., Warsaw, IN. Used to mate the inserter with the shell implant.
- Z-0072-2011 · Mar 19, 2010 · TerminatedContinuum Acetabular Systems Shell Inserter Adapter without Rotational Control, 00-8790-003-10, Zimmer Inc., Warsaw, IN. Used to mate the inserter with the shell implant.
Other PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices
- PINNACLE 1217-25-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED735 reports
- NA 1365-52-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED683 reports
- APEX 1246-03-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED3 deaths613 reports
- PINNACLE 1217-20-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED2 deaths590 reports
- PINNACLE 1217-30-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED1 death484 reports
- NA 1365-53-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED404 reports
- PINNACLE ALTRX 1221-36-054Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED388 reports
- PINNACLE ALTRX 1221-32-050Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED386 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page