NexGen® Legacy® 5994-17-92Recalls & reported problems
Zimmer, Inc. · Class 2 · Implant
All models of NexGen Legacy (119)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00889024224858), received between Nov 6, 2020 and Dec 4, 2023 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Loss of or Failure to Bond” (1 report).
23 other recalls cover devices cleared under the same FDA submission (K173057, K960279); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Loss of or Failure to Bond1
- Manufacturing, Packaging or Shipping Problem1
- Packaging Problem1
- Tear, Rip or Hole in Device Packaging1
- Unstable1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Insufficient Information1
- No Patient Involvement1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 4, 2023Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18257605 ↗MalfunctionDec 12, 2022Packaging Problem; Packaging Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15958809 ↗InjuryOct 21, 2021Loss of or Failure to Bond; Unstable; Loss of or Failure to Bond; Unstable
IT WAS REPORTED PATIENT UNDERWENT A REVISION PROCEDURE THREE YEARS POST IMPLANTATION DUE TO INSTABILITY AND LOOSENING OF THE TIBIAL COMPONENTS. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 12672327 ↗MalfunctionNov 6, 2020Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
DEVICE WAS RETURNED WITH PACKAGING DAMAGE AND STERILITY BARRIER WAS COMPROMISED.
Patient problems: No Patient Involvement
MAUDE report 10801663 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K173057, K960279. One submission often covers many models, so check the product and lot details in each record.
- Z-1039-2025 · Jan 6, 2025 · Open, ClassifiedNexGen LCCK Legacy Articular Surface with Locking Screw - Striped Yellow/E,F - Height 10 mm, Item Number 00-5994-032-10
- Z-1038-2025 · Jan 6, 2025 · Open, ClassifiedNexGen LCCK Legacy Articular Surface with Locking Screw - Striped Purple/C,D - Height 14 mm, Item Number 00-5994-022-14
- Z-2092-2023 · May 19, 2023 · TerminatedNexGen Precoat Stemmed Tibial Plate Size 5
- Z-0321-2020 · Oct 10, 2019 · TerminatedVarious Knee Systems for knee joint arthroplasty, knee prosthesis, Item Nos. 00522000100 00522000200 00522000300 00522000400 00522006304 00522006504 00522006600 00522006800
- Z-1036-2018 · Nov 29, 2017 · TerminatedLPS FEM COMP SZ B-L LPS FEM COMP SZ B-R LPS FEM COMP SZ C-L LPS FEM COMP SZ C-R LPS FEM COMP SZ D-L LPS FEM COMP SZ D-R LPS FEM COMP SZ E-L LPS FEM COMP SZ E-R LPS FEM COMP SZ F-L
- Z-1035-2018 · Nov 29, 2017 · TerminatedLPS OPTION FEMORAL C-L LPS OPTION FEMORAL C-R LPS OPTION FEMORAL D-L LPS OPTION FEMORAL D-R LPS OPTION FEMORAL E-L LPS OPTION FEMORAL E-R LPS OPTION FEMORAL F-L LPS OPTION FEMORAL
- Z-1040-2018 · Nov 29, 2017 · TerminatedLPS PRECOAT FEM SIZE D-RT LPS PRECOAT FEM SIZE E-RT LPS POROUS FEM SIZE F-RT This device is indicated for patients with severe knee pain and disability
- Z-1037-2018 · Nov 29, 2017 · TerminatedLCCK FEM IMPLANT SZ C-L LCCK FEM IMPLANT SZ C-R LCCK FEM IMPLANT SZ D-R LCCK FEM IMPLANT SZ E-L LCCK FEM IMPLANT SZ E-R LCCK FEM IMPLANT SZ F-L LCCK FEM IMPLANT SZ F-R This device
- Z-1034-2018 · Nov 29, 2017 · TerminatedLPS FEM IMPLANT SZ H-R This device is indicated for patients with severe knee pain and disability
- Z-0834-2016 · Jan 11, 2016 · TerminatedNexGen Knee LPS Porous FEM NexGen Knee LPS Option FEM NexGen Knee Lock FEM prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer various sizes Pr
- Z-1146-2016 · Jan 11, 2016 · TerminatedProduct 48 consists of all product under product code: JWH and same usage: Item no: 597206526 NEXGEN ALL-POLY PATELLA, for use in total knee arthroplasty
- Z-1575-2015 · Apr 2, 2015 · TerminatedNexGen Augment; 5mm Distal Femoral Augment;Part number 00-5990-036-10. Intended to be used in total knee arthroplasty when there is insufficient bone in the distal femur.
- Z-1023-2014 · Oct 11, 2013 · TerminatedMODULAR CUP NEUTRAL LINER MODULAR CUP 10 DEGREE LIN MODULAR CUP 20 DEGREE LIN MODULAR CUP 7MM OFFSET LI
- Z-0531-2011 · Sep 15, 2010 · TerminatedZimmer, NexGen Complete Knee Solution LPS Femoral Component, Size F Right, sterile, REF 00-5996-016-02.
- Z-0536-2011 · Sep 15, 2010 · TerminatedZimmer, NexGen Complete Knee Solution LPS Flex Gender Femoral Component, Size E Right, sterile, REF 00-5764-015-52.
…and 8 more.
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page