PERSONA® Vivacit-E® 42-5124-008-10Recalls & reported problems
Zimmer, Inc. · Class 2 · Implant
All models of PERSONA Vivacit-E (285)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00889024237322), received between Apr 22, 2025 and Aug 24, 2026 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Naturally Worn” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K121771); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Naturally Worn2
- Difficult to Insert1
- Fracture1
- Positioning Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Pain2
- Failure of Implant1
- Joint Laxity1
- Metal Related Pathology1
- Scar Tissue1
- Swelling/ Edema1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 24, 2026Difficult to Insert
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50411087 ↗InjuryDec 8, 2025Fracture; Naturally Worn; Fracture; Naturally Worn
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Joint Laxity; Pain
MAUDE report 23747563 ↗MalfunctionSep 6, 2025Positioning Failure; Positioning Failure
IT WAS REPORTED THAT THE SURGEON COULD NOT LOCK DOWN THE ARTICULAR SURFACE DESPITE IT BEING IN THE RIGHT POSITION. SURGEON TRIED A FEW TIMES BUT STILL COULDN¿T HEAR THE LOCK, VISIBLY NOT LOCKED IN AS WELL. THEY REQUESTED TO OPEN A NEW ONE AND MANAGE TO LOCK IT IN. ATTEMPTS HAVE BEEN MADE, AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22988387 ↗InjuryApr 22, 2025Naturally Worn; Naturally Worn
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL LEFT KNEE ARTHROPLASTY. SUBSEQUENTLY, THE PATIENT DEVELOPED PAIN, SWELLING, AND THERE WAS CONCERN FOR PROSTHESIS FAILURE ON RADIOGRAPH. THE PATIENT WAS REVISED WITH PLACEMENT OF COMPETITOR PRODUCT APPROXIMATELY 5 YEARS AND 3 MONTHS POST IMPLANTATION. THE INITIAL PATELLA WAS RETAINED. INTRA-OPERATIVE FINDINGS INCLUDED SCAR TISSUE, SIGNIFICANT POLY WEAR, AND METALLOSIS. NO FURTHER DETAILS HAVE BEEN PROVIDED AT THIS TIME.
Patient problems: Failure of Implant; Metal Related Pathology; Pain; Scar Tissue; Swelling/ Edema
MAUDE report 21882284 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K121771. One submission often covers many models, so check the product and lot details in each record.
- Z-1917-2016 · May 11, 2016 · TerminatedPersona Trabecular Metal Tibia; Persona Trabecular Metal Tibial Plate Instruments and Modular Brackets; Used to facilitate the implantation of joint replacement implants.
- Z-1266-2015 · Jan 28, 2015 · TerminatedPersona Trabecular Metal Tibial Plate / Persona TM Tibia-Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer For use in eit
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page