Sidus® Stem-Free Shoulder 01.04555.460Recalls & reported problems
Zimmer GmbH · Class 2 · Implant
All models of Sidus Stem-Free Shoulder (9)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024415942), received between Aug 2, 2023 and Aug 2, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- Failure of Implant1
- Joint Dislocation1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 2, 2023Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT PATIENT WITH TOTAL SHOULDER PROSTHESIS HAS BEEN REVISED FOUR (4) YEARS AFTER INITIAL SURGERY DUE TO PAIN, LINER FRACTURE AND DISLOCATION. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Failure of Implant; Joint Dislocation; Pain
MAUDE report 17441502 ↗
Other Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained devices
- Tornier Perform DWM003ATornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- Sidus® Stem-Free Shoulder 01.04555.500Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- DJO SURGICAL 520-08-021Encore Medical, L.P. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained20 reports
- INHANCE 5200-00-036Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained17 reports
- Easytech Anatomical Shoulder System 314-0038Fx Solutions · Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained14 reports
- Tornier Simpliciti® Shoulder System 7122872Tornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained9 reports
- Sidus® Stem-Free Shoulder 01.04555.110Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
- GLOBAL ICON 1140-10-054Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page