Zimmer GmbH · BIOLOX® DELTA, CERAMIC FEMORAL HEAD, XL, Ø 36/+7, TAPER 12/14 · Class 2 · Implant

All models of Biolox delta (16)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 00889024430389), received between Nov 13, 2019 and May 2, 2025 — classified as 9 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 2 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Dislodged or Dislocated2
  • Fracture2
  • Insufficient Device Problem Information2
  • Unstable2
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Packaging Problem1
  • Tear, Rip or Hole in Device Packaging1

Patient problems

  • Failure of Implant3
  • Joint Dislocation3
  • Bone Fracture(s)2
  • Adhesion(s)1
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Hematoma1
  • Joint Laxity1
  • Low Blood Pressure/ Hypotension1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 2, 2025Fracture; Fracture

    IT WAS REPORTED PATIENT UNDERWENT HIP REVISION APPROXIMATELY 8 MONTHS POST IMPLANTATION DUE TO THE PATIENT HEARD A CRACKING SOUND AND UPON SITTING HEARD A WEIRD SOUND AND IMMEDIATELY FELT SOMETHING WAS WRONG. IT WAS LATER FOUND THAT THE HEAD COMPONENT HAD FRACTURED, AND THE PATIENT WAS REVISED APPROXIMATELY 8 MONTHS POST-IMPLANTATION. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.

    Patient problems: Failure of Implant

    MAUDE report 21950880 ↗
  • InjuryMar 19, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THE PATIENT UNDERWENT AN INITIAL RIGHT TOTAL HIP ARTHROPLASTY. SUBSEQUENTLY, PRIOR TO OUTPATIENT DISCHARGE, POST-OPERATIVE ORTHOSTATIC HYPOTENSION AND A RIGHT POSTEROLATERAL HEMATOMA WERE NOTED. THE PATIENT WAS TRANSFERRED FROM THE SURGERY CENTER AND ADMITTED TO A HOSPITAL FACILITY FOR OBSERVATION AND MEDICAL INTERVENTION. SYMPTOMS RESOLVED AND THE PATIENT WAS DISCHARGED TWO DAYS LATER. THE STUDY HAS SINCE BEEN COMPLETED PER PROTOCOL WITH NO FURTHER COMPLICATIONS OR ALLEGATIONS AGAINST THE DEVICE, ALL INITIAL PRODUCT REMAINS IMPLANTED. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.

    Patient problems: Hematoma; Low Blood Pressure/ Hypotension

    MAUDE report 18928621 ↗
  • InjuryMar 4, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT PATIENT UNDERWENT REVISION APPROXIMATELY 6 YEARS POST IMPLANTATION DUE TO DISLOCATION. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.

    Patient problems: Failure of Implant; Joint Dislocation

    MAUDE report 18827428 ↗
  • InjuryJan 9, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A SMALL FEMORAL FRACTURE WAS NOTED AND SECURED WITH CERCLAGE WIRE WHEN IMPLANTING THE CLS STEM. THEN, ON POST-OP X-RAYS THE FRACTURE WAS FOUND TO BE MUCH WORSE AND REQUIRED FURTHER SURGERY. CLS STEM WAS REMOVED, AND FRACTURE STABILIZED WITH WIRES ON REVISION SURGERY. DILIGENCE IS COMPLETE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.

    Patient problems: Bone Fracture(s)

    MAUDE report 18475361 ↗
  • InjurySep 13, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A HIP PROCEDURE AND SUBSEQUENTLY HAD TO UNDERGO A REVISION THE NEXT DAY DUE TO A DISLOCATION. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Joint Dislocation

    MAUDE report 17734464 ↗
  • MalfunctionApr 25, 2023Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging

    IT WAS REPORTED THAT UPON OPENING THE CERAMIC HEAD, THE STERILE PACKAGING WAS FOUND TO BE DAMAGED CAUSING A STERILITY BREACH. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16805112 ↗
  • InjuryMay 30, 2022Unstable; Unintended Movement; Loosening of Implant Not Related to Bone-Ingrowth; Unstable; Unintended Movement; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT: THE PATIENT UNDERWENT A REVISION SURGERY APPROXIMATELY 1 MONTH AFTER THE IMPLANTATION DUE TO PERIPROSTHETIC INSTABILITY AND BONE FRACTURE. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Bone Fracture(s); Joint Dislocation

    MAUDE report 14539625 ↗
  • InjuryApr 11, 2022Fracture; Fracture

    REVISION DUE TO IMPLANT FRACTURE. IT WAS REPORTED THAT THE CERAMIC HEAD FRACTURED AND BROKE IN THE PATIENT. PATIENT OUTCOME - REVISION SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 14074942 ↗
  • InjuryOct 7, 2021Unstable; Insufficient Device Problem Information; Unstable; Insufficient Device Problem Information

    NO EVENT UPDATE. INVESTIGATION RESULTS ARE NOW AVAILABLE.

    Patient problems: Adhesion(s); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Joint Laxity; Scar Tissue

    MAUDE report 12589524 ↗
  • InjuryNov 28, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    PATIENT WAS IMPLANTED ON THE LEFT SIDE AND UNDERWENT REVISION SURGERY DUE TO INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 9390019 ↗
  • MalfunctionNov 13, 2019Packaging Problem; Packaging Problem

    PLEASE REFER TO REPORT 0009613350-2019-00676.

    Patient problems: No Information

    MAUDE report 9314588 ↗

Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices →