PERSONA® Vivacit-E® 42-5121-008-14Recalls & reported problems
Zimmer, Inc. · Class 2 · Implant
All models of PERSONA Vivacit-E (285)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024469334), received between Nov 2, 2023 and Nov 2, 2023 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Ambulation or Postural Difficulties1
- Hyperextension1
- Joint Laxity1
- Necrosis1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 2, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A LEFT KNEE ARTHROPLASTY REVISION TO ADDRESS PAIN, STIFFNESS, POPPING SENSATIONS, LIGAMENT LAXITY, INSTABILITY AND LIMITED ABILITY TO PERFORM DAILY ACTIVITIES APPROXIMATELY FIFTEEN (15) MONTHS POST-OPERATIVELY. THE ARTICULAR SURFACE AND FEMORAL COMPONENT WERE REVISED AND REPLACED AND A TIBIAL STEM ADDED. INITIAL OPERATIVE NOTES NOTED NO INTRAOPERATIVE COMPLICATIONS. THE PATIENT WAS DISCHARGED ON (B)(6) 2022 WITH AT HOME THERAPY. REVISION OPERATIVE NOTES NOTED THE PATIENT'S PAIN BEGAN APPROXIMATELY SIX (6) MONTHS PRIOR, LIMITING DAILY ACTIVITY, AND THE PATIENT WAS ALSO EXPERIENCING INSTABILITY. DURING THE PROCEDURE, SEVERE VARUS-VALGUS LAXITY AND HYPEREXTENSION WERE NOTED. THE FEMORAL COMPONENT WAS IN GOOD ALIGNMENT AND REMOVED WITHOUT DIFFICULTY. SCLEROTIC AND NON-VIABLE BONE REQUIRED REMOVAL FROM THE FEMUR PRIOR TO PLACING THE NEW FEMORAL COMPONENT. A SEQUENTIALLY LARGER ARTICULAR SURFACE WAS USED TO ACHIEVE STABILITY AND THE TIBIAL BASEPLATE WAS PUNCHED TO ACCOMMODATE THE TIBIAL STEM. NO INTRAOPERATIVE COMPLICATIONS WERE IDENTIFIED.
Patient problems: Ambulation or Postural Difficulties; Hyperextension; Joint Laxity; Necrosis; Pain
MAUDE report 18061912 ↗
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page