Anatomical Shoulder™ 01.04201.123Recalls & reported problems

Zimmer GmbH · Class 2 · Implant

All models of Anatomical Shoulder (33)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00889024484924), received between Jun 9, 2023 and Feb 18, 2025 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Pain2
  • Extraskeletal ossification1
  • Loss of Range of Motion1
  • Osteolysis1
  • Scar Tissue1
  • Subluxation1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Extraskeletal ossification; Osteolysis; Pain

    MAUDE report 21396169 ↗
  • InjuryJun 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH A CLINICAL STUDY THAT A PATIENT UNDERWENT AN INITIAL RIGHT TOTAL SHOULDER ARTHROPLASTY APPROXIMATELY SIX (6) YEARS AGO. APPROXIMATELY SEVEN (7) MONTHS AFTER IMPLANTATION, THE PATIENT HAD DEVELOPED PAIN. ABOUT ONE AND HALF (1,5) YEARS LATER, INFECTION WAS RULED OUT AND COMPONENTS WERE FOUND TO BE STABLE, HOWEVER EXTENSIVE DEBRIDEMENT OF INTRA-AND EXTRA-ARTICULAR SCAR TISSUE WAS REQUIRED. THE HEAD WAS NOTED TO BE SLIGHTLY OVERSTUFFED AND SOMEWHAT SUBLUXATED VENTRALLY. AS OF THE FIVE (5) YEAR STUDY FOLLOW-UP VISIT, THE PATIENT IS SATISFIED AND ABLE TO COMPLETE THE MAJORITY OF DAILY ACTIVITIES WITH MINIMAL PAIN. THERE HAVE BEEN NO OTHER ADVERSE EVENTS OR COMPLICATIONS REPORTED. THE ORIGINAL STUDY COMPONENTS REMAIN IMPLANTED. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Loss of Range of Motion; Pain; Scar Tissue; Subluxation

    MAUDE report 17097482 ↗

Other shoulder prosthesis, reverse configuration devices

All shoulder prosthesis, reverse configuration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page