Zimmer Biomet™ 89-8522-450-20Recalls & reported problems
Zimmer Surgical SA · Class 1
All models of Zimmer Biomet (17)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00889024521315), received between Nov 8, 2023 and Feb 18, 2025 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Mechanical Jam” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Jam6
- Mechanical Problem3
- Overheating of Device2
- Difficult to Insert1
- Explosion1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- Insufficient Information1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 18, 2025Mechanical Jam; Mechanical Jam
IT WAS REPORTED THAT THE MOTOR STOPPED WORKING DURING SURGERY WITH THE RECIPROCATING SAW ATTACHMENT ON. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21392920 ↗MalfunctionFeb 12, 2025Mechanical Jam; Mechanical Jam
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21362842 ↗MalfunctionFeb 10, 2025Explosion; Explosion
IT WAS REPORTED THAT THE RECIPROCATING SAW ATTACH EXPLODED. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Patient problems: Insufficient Information
MAUDE report 21341924 ↗MalfunctionDec 20, 2024Overheating of Device; Mechanical Jam; Overheating of Device; Mechanical Jam
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20986930 ↗MalfunctionDec 19, 2024Mechanical Problem; Mechanical Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20974011 ↗MalfunctionNov 7, 2024Mechanical Jam; Mechanical Jam
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20628715 ↗MalfunctionOct 2, 2024Overheating of Device; Mechanical Jam; Overheating of Device; Mechanical Jam
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20350992 ↗MalfunctionAug 27, 2024Mechanical Problem; Mechanical Jam; Mechanical Problem; Mechanical Jam
IT WAS REPORTED THAT THE RECIPROCATING SAW SUDDENLY STOPPED DURING PROCEDURE. ANOTHER SAW WAS USED TO FINISH SURGERY. THIS EVENT IS RELATED TO A MALFUNCTION THAT COULD POTENTIALLY LEAD TO A SERIOUS INJURY. HOWEVER, NO PATIENT HARM OR FURTHER OUTCOME WAS REPORTED. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20074362 ↗MalfunctionJul 29, 2024Mechanical Problem; Mechanical Problem
IT WAS REPORTED THAT DURING THE INITIAL SURGERY, THE RECIPROCATING SAW ATTACHMENT STOPPED. THIS EVENT IS RELATED TO A MALFUNCTION THAT COULD POTENTIALLY LEAD TO A STERILITY ISSUE/SERIOUS INJURY. HOWEVER, NO PATIENT HARM OR FURTHER OUTCOME WAS REPORTED. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19848986 ↗MalfunctionNov 8, 2023Difficult to Insert; Difficult to Insert
IT WAS REPORTED THAT PIN COLLET WOULD NOT HOLD THE PIN. THIS EVENT IS RELATED TO A MALFUNCTION THAT COULD POTENTIALLY LEAD TO A SERIOUS INJURY. HOWEVER, NO PATIENT HARM OR FURTHER OUTCOME WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18090373 ↗
Other Motor, Surgical Instrument, Ac-Powered devices
- NA 05.001.201Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED1,902 reports
- NA 530.710Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED1,800 reports
- NA 530.705Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED1,492 reports
- NA 530.715Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED390 reports
- NA 530.730Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED267 reports
- NA 05.001.240Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED262 reports
- KINCISE™ 1000-00-101Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED242 reports
- NA 530.791Synthes GmbH · MOTOR, SURGICAL INSTRUMENT, AC-POWERED84 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page