Skip to content

NexGen® Legacy® 5964-40-12 (REF 00-5964-040-12)Recalls & reported problems

Zimmer, Inc. · Class 2 · Implant

All models of NexGen Legacy (119)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00889024635005), received between Aug 22, 2023 and Dec 30, 2024 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Naturally Worn” (2 reports).

9 other recalls cover devices cleared under the same FDA submission (K173057, K991581); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Naturally Worn2
  • Insufficient Device Problem Information1
  • Material Erosion1
  • Pitted1
  • Positioning Failure1

Patient problems

  • Pain3
  • Swelling/ Edema3
  • Ambulation or Postural Difficulties2
  • Arthritis1
  • Bone Fracture(s)1
  • Cyst(s)1
  • Failure of Implant1
  • Impaired Healing1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Impaired Healing

    MAUDE report 21034478 ↗
  • InjuryAug 22, 2024Material Erosion; Naturally Worn; Adverse Event Without Identified Device or Use Problem; Material Erosion; Naturally Worn; Adverse Event Without Identified Device or Use Problem

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Ambulation or Postural Difficulties; Arthritis; Cyst(s); Loss of Range of Motion; Pain; Swelling/ Edema

    MAUDE report 20039951 ↗
  • InjuryJun 18, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL BILATERAL TOTAL KNEE ARTHROPLASTY. APPROXIMATELY 6 YEARS POST-OP, THE PATIENT STATED HIS LEFT KNEE HAS FAILED AND WAS EXPERIENCING PAIN AND DIFFICULTY WEIGHT-BEARING. UPON MEDICAL EVALUATION, REVISION HAS BEEN RECOMMENDED BUT HAS NOT BEEN SCHEDULED. ATTEMPTS HAVE BEEN MADE AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.

    Patient problems: Ambulation or Postural Difficulties; Osteolysis; Pain; Swelling/ Edema

    MAUDE report 19561123 ↗
  • InjuryJan 30, 2024Pitted; Naturally Worn; Insufficient Device Problem Information; Pitted; Naturally Worn; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL LEFT TOTAL KNEE ARTHROPLASTY . SUBSEQUENTLY, THE PATIENT REPORTED A PAINFUL LEFT KNEE WITH SWELLING. X-RAYS SHOWED LUCENCY AROUND THE TIBIAL COMPONENT. SUBSEQUENTLY, THE PATIENT UNDERWENT A LEFT TOTAL KNEE REVISION APPROXIMATELY 5 YEARS POST-OP. DURING THE REVISION, THE SURGEON NOTED SYNOVITIS, POLY WEAR AND PITTING, AND TIBIAL LOOSENING. ALL COMPONENTS WERE REVISED WITHOUT COMPLICATIONS. ATTEMPTS HAVE BEEN MADE AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.

    Patient problems: Bone Fracture(s); Failure of Implant; Insufficient Information; Joint effusion; Pain; Radiolucent Lines; Swelling/ Edema; Synovitis

    MAUDE report 18610051 ↗
  • MalfunctionAug 22, 2023Positioning Failure; Positioning Failure

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17596183 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K173057, K991581. One submission often covers many models, so check the product and lot details in each record.

  • Z-2092-2023 · May 19, 2023 · Terminated
    NexGen Precoat Stemmed Tibial Plate Size 5
  • Z-0321-2020 · Oct 10, 2019 · Terminated
    Various Knee Systems for knee joint arthroplasty, knee prosthesis, Item Nos. 00522000100 00522000200 00522000300 00522000400 00522006304 00522006504 00522006600 00522006800
  • Z-1045-2018 · Nov 29, 2017 · Terminated
    NEXGEN LPS-FLEX PRECOAT FEMORAL SIZE E-LT This device is indicated for patients with severe knee pain and disability
  • Z-1044-2018 · Nov 29, 2017 · Terminated
    LPS-FLEX PRECOAT FEMORAL B-R LPS-FLEX PRECOAT FEMORAL C-L LPS-FLEX PRECOAT FEMORAL C-R LPS-FLEX PRECOAT FEMORAL D-L LPS-FLEX PRECOAT FEMORAL D-R LPS-FLEX PRECOAT FEMORAL E-L LPS-FL
  • Z-1043-2018 · Nov 29, 2017 · Terminated
    LPS-FLEX OPTION FEMORAL C-L LPS-FLEX OPTION FEMORAL C-L LPS-FLEX OPTION FEMORAL C-R LPS-FLEX OPTION FEMORAL D-L LPS-FLEX OPTION FEMORAL D-R LPS-FLEX OPTION FEMORAL E-L LPS-FLEX OPT
  • Z-1152-2016 · Jan 11, 2016 · Terminated
    Product 54 consists of all product under product code: JWH and same usage: Item no: 596009900 NEXGEN TAPER PLUG for use in total knee arthroplasty
  • Z-0832-2016 · Jan 11, 2016 · Terminated
    NexGen LPS-FLEX Option Femoral NexGen LPS-FLEX Precoat Femoral prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer various sizes Product Usage
  • Z-1023-2014 · Oct 11, 2013 · Terminated
    MODULAR CUP NEUTRAL LINER MODULAR CUP 10 DEGREE LIN MODULAR CUP 20 DEGREE LIN MODULAR CUP 7MM OFFSET LI
  • Z-0609-2011 · Apr 16, 2010 · Terminated
    NexGen Complete Knee Solution Stemmed tibial broach impactor, Catalog # 00-5977-011-00, Zimmer Inc., Warsaw, IN.

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page