Skip to content

CREO 5067.0631SRecalls & reported problems

Globus Medical, Inc. · CREO 4.75, 6.5 x 30mm HA Coated Monoaxial Screw · Class 2

All models of CREO (100)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889095339635), received between Mar 4, 2024 and Mar 4, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Improper or Incorrect Procedure or Method1

Patient problems

  • Spinal Cord Injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 4, 2024Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    THE PATIENT WAS TREATED USING ANTERIOR TETHERING FOR ADOLESCENT IDIOPATHIC SCOLIOSIS IN TURKEY TWO MONTHS PRIOR TO REVISION. THE PATIENT IS A 15 YEAR OLD UK CITIZEN, TAKEN ABROAD FOR SURGERY BY PARENTS. PRESENTED TO OUR UNIT WITH TWO LITRE HAEMOTHORAX. AT REVIEW TWO SCREWS ADJACENT TO DESCENDING AORTA, TWO SCREWS ERODED THROUGH THE DIAPHRAGM AND TWO SCREWS COMPRESSING RENAL ARTERY AND ADRENAL GLAND.

    Patient problems: Spinal Cord Injury

    MAUDE report 18831759 ↗

Other ORTHOSIS, SPINAL PEDICLE FIXATION devices

All ORTHOSIS, SPINAL PEDICLE FIXATION devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page