Skip to content

JAWS® Nitinol Staple System P72-020-2020-SRecalls & reported problems

Paragon 28, Inc. · JAWs Great White Nitinol Staple System, 20 x 20 x 20mm, Straight Staple Kit · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00889795124227), received between Jan 24, 2024 and Jan 24, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Physical Resistance/Sticking2
  • Unintended Movement2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 24, 2024Unintended Movement; Physical Resistance/Sticking; Unintended Movement; Physical Resistance/Sticking

    THE METAL RADIOPAQUE PIECE ON THE INSIDE OF THE DRILL GUIDE HAD GOTTEN STUCK AND WELDED ITSELF ONTO THE DRILL DURING THE PROCEDURE. THIS HAPPENED ON TWO STAPLE KITS. THE SURGERY WAS SUCCESSFULLY COMPLETED BUT WAS DELAYED BY APPROXIMATELY 3 MINUTES. THIS IS REPORT 1 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18572481 ↗
  • MalfunctionJan 24, 2024Unintended Movement; Physical Resistance/Sticking; Unintended Movement; Physical Resistance/Sticking

    THE METAL RADIOPAQUE PIECE ON THE INSIDE OF THE DRILL GUIDE HAD GOTTEN STUCK AND WELDED ITSELF ONTO THE DRILL DURING THE PROCEDURE. THIS HAPPENED ON TWO STAPLE KITS. THE SURGERY WAS SUCCESSFULLY COMPLETED BUT WAS DELAYED BY APPROXIMATELY 3 MINUTES. THIS IS REPORT 2 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18572479 ↗

Other Staple, fixation, bone devices

All Staple, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page