PRO-DENSE™ 87SR0100Recalls & reported problems
Wright Medical Technology, Inc. · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00889797072762), received between Jul 28, 2021 and Oct 14, 2022 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Device Difficult to Setup or Prepare3
- Coagulation in Device or Device Ingredient2
- Difficult to Insert1
- Material Too Rigid or Stiff1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 14, 2022Difficult to Insert; Device Difficult to Setup or Prepare; Difficult to Insert; Device Difficult to Setup or Prepare
IT WAS REPORTED THAT THE 10CC PRODENSE UNIT WAS MIXED AND UPON DELIVERY WOULD NOT EXIT THE DELIVERY NEEDLE AFTER 4 MINUTES WHEN FILLING SCREW TRACKS IN THE HIP AFTER HARDWARE WAS REMOVED. 2 OF THE THREE SCREW HOLES WERE FILLED BEFORE THE PRODENSE WOULD NOT EXIT THE DELIVERY NEEDLE. ONE SCREW HOLE WAS NOT FILLED WITH PRODENSE. THIS RESULTED IN A 3-4 MINUTE DELAY IN SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15606339 ↗MalfunctionMar 3, 2022Coagulation in Device or Device Ingredient; Device Difficult to Setup or Prepare; Coagulation in Device or Device Ingredient; Device Difficult to Setup or Prepare
IT WAS REPORTED THAT DURING THE PROCEDURE THE PHYSICIAN MIXED MONOMER INTO MIXER AND MATERIAL, MIXED FOR 30 SECS HORIZONTAL, SWITCHED CAPS AND WENT TO DELIVER AFTER ALL ATTACHMENTS CONNECTED AND MATERIAL WAS HARD BEFORE THE 5 MINS MARK. THE SURGICAL STAFF DID THIS PROCESS TWICE WITH ANOTHER 10CC AND ANOTHER LOT NUMBER AND WHILE ATTEMPTING INJECTION THE MATERIAL HARDENED PREVENTING THE INJECTION. THEY OPENED A SECOND BATCH OF PRODENSE AND THAT DID THE EXACT SAME THING. THE STAFF CONVERTED TO CERAMENT TO FINISH THE CASE. THE SUBSTITUTE (CERAMENT) WAS ONLY 5CC¿S AND THEY NEEDED A TOTAL OF 15-20CC¿S FOR THE CASE. A SURGICAL DELAY WAS REPORTED; HOWEVER THE LENGTH OF THE DELAY WAS NOT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13664050 ↗MalfunctionMar 3, 2022Coagulation in Device or Device Ingredient; Device Difficult to Setup or Prepare; Coagulation in Device or Device Ingredient; Device Difficult to Setup or Prepare
IT WAS REPORTED THAT DURING THE PROCEDURE THE PHYSICIAN MIXED MONOMER INTO MIXER AND MATERIAL, MIXED FOR 30 SECS HORIZONTAL, SWITCHED CAPS AND WENT TO DELIVER AFTER ALL ATTACHMENTS CONNECTED AND MATERIAL WAS HARD BEFORE THE 5 MINS MARK. THE SURGICAL STAFF DID THIS PROCESS TWICE WITH ANOTHER 10CC AND ANOTHER LOT NUMBER AND WHILE ATTEMPTING INJECTION THE MATERIAL HARDENED PREVENTING THE INJECTION. THEY OPENED A SECOND BATCH OF PRODENSE AND THAT DID THE EXACT SAME THING. THE STAFF CONVERTED TO CEREMENT TO FINISH THE CASE. THE SUBSTITUTE (CEREMENT) WAS ONLY 5CC¿S AND THEY NEEDED A TOTAL OF 15-20CC¿S FOR THE CASE. A SURGICAL DELAY WAS REPORTED; HOWEVER THE LENGTH OF THE DELAY WAS NOT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13664041 ↗MalfunctionJul 28, 2021Material Too Rigid or Stiff; Material Too Rigid or Stiff
IT WAS REPORTED THAT THE PRODENSE HARDENED TOO QUICKLY AND WAS NOT ABLE TO BE INJECTED INTO THE PATIENT. THERE WAS A BACKUP SOLUTION FROM ANOTHER COMPANY THAT WAS ABLE TO BE USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12237496 ↗
FDA clearance and classification
The FDA regulates product code MQV (filler, bone void, calcium compound) under 21 CFR 888.3045 as a Class II device. 21 CFR 888.3045 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the PRO-DENSE™ 87SR0100
Has the PRO-DENSE™ 87SR0100 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00889797072762), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PRO-DENSE™ 87SR0100?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Jul 28, 2021 and Oct 14, 2022. In those reports, the most common specific device problems are “Device Difficult to Setup or Prepare” (3), “Coagulation in Device or Device Ingredient” (2) and “Difficult to Insert” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PRO-DENSE™ 87SR0100?
None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PRO-DENSE™ 87SR0100 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.
Who makes the PRO-DENSE™ 87SR0100, and is it still sold?
The FDA's device database lists Wright Medical Technology, Inc. as the company responsible for it (brand PRO-DENSE™, model 87SR0100). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other FILLER, BONE VOID, CALCIUM COMPOUND devices
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44150Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND3 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42275Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44145Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42200Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42280Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- MAGNIFUSE® Bone Graft 7509014Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T43102Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- HydroSet XT 897005Stryker Corporation · FILLER, BONE VOID, CALCIUM COMPOUND1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page