Spiration Valve System HUS-C26NRecalls & reported problems
Gyrus Acmi, Llc · Deployment Catheter and Loader, 2.6 · Class f
All models of Spiration Valve System (10)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00896506002187), received between May 13, 2023 and Jun 23, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Failure to Eject” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Failure to Eject1
- Insufficient Device Problem Information1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 23, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
A PATIENT UNDERWENT SPIRATION VALVE PLACEMENT FOR THE TREATMENT OF AIR LEAK ON (B)(6) 2023. DURING THE PROCEDURE, THE PHYSICIAN NOTED THAT THE LOADED VALVE (HUS-V6) WAS POPPING OUR OR NOT FULLY INSERTED IN THE DEPLOYMENT CATHETER (HUS-C26N). THE VALVE WAS REMOVED FROM THE DEPLOYMENT CATHETER. AS A NEW VALVE (HUS-V9) WAS BEING LOADED, THE VALVE LOADER WAS DROPPED AND DAMAGED (I.E., IT WAS BROKEN AND COULD NO LONGER BE USED). A SECOND VALVE DEPLOYMENT CATHETER AND LOADER WAS NOT AVAILABLE AT THE TIME, RESULTING IN A DELAY OF THE PROCEDURE. THE PATIENT WAS MOVED FROM THE OR TO THE ICU FOR A PERIOD OF TIME UNTIL A NEW VALVE DEPLOYMENT CATHETER AND LOADER WAS ACQUIRED. THE VALVE PLACEMENT PROCEDURE WAS ATTEMPTED AGAIN THE SAME DAY ((B)(6) 2023). THE PHYSICIAN TRIED TO IMPLANT TWO DIFFERENT SIZED VALVES (HUS-V6 AND HUS-V9) BUT WAS UNSUCCESSFUL BECAUSE THE THERAPEUTIC BRONCHOSCOPE BEING USED COULD NOT ARTICULATE THE INTENDED ANATOMY. THE NEXT DAY ((B)(6) 2023 ) THE VALVE PLACEMENT PROCEDURE WAS INITIATED FOR A THIRD TIME USING A NEW VALVE DEPLOYMENT CATHETER AND LOADER. IN ADDITION, A DIFFERENT BRONCHOSCOPE WAS USED FOR THIS PROCEDURE. VALVE PLACEMENT WAS COMPLETED SUCCESSFULLY AND THE PA
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17195823 ↗MalfunctionMay 13, 2023Failure to Eject; Failure to Eject
PATIENT WAS TO HAVE SPIRATION VALVES (HUS-V9) PLACED FOR THE TREATMENT OF AIR LEAK (DATE UNKNOWN). PHYSICIAN USED THE SPIRATION DEPLOYMENT CATHETER AND LOADER (HUS-C26N) TO PLACE THE SPIRATION VALVES. VALVES COULD NOT BE PLACED. PHYSICAN REPORTED THREE WASTED VALVES (HUS-V9) DUE TO A MALFUNCTIONING DEPLOYMENT CATHETER AND LOADER (HUS-C26N). REPLACEMENT DEVICES WERE SENT RESULTING IN A 24-HOUR DELAY IN PROCEDURE. NO PATIENT INJURY OCCURRED.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 16925146 ↗
Other One-Way Air-Leak Valve devices
- Spiration Valve System HUS-V9Gyrus Acmi, Llc · One-Way Air-Leak Valve4 deaths6 reports
- Spiration Valve System HUS-V7Gyrus Acmi, Llc · One-Way Air-Leak Valve2 deaths3 reports
- Spiration Valve System HUS-V6Gyrus Acmi, Llc · One-Way Air-Leak Valve2 reports
- Spiration Valve System HUS-V5Gyrus Acmi, Llc · One-Way Air-Leak Valve1 death1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page