Skip to content

Todd Hewitt Broth + AntibioticsRecalls & reported problems

Biomerieux SA · selective enrichment broth for the detection of group B streptococci in pregnant women. · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03573026118723), received between Apr 4, 2023 and Apr 4, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “False Negative Result” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • False Negative Result1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 4, 2023False Negative Result; False Negative Result

    INTENDED USE: TODD-HEWITT BROTH + ANTIBIOTICS IS A SELECTIVE ENRICHMENT BROTH FOR THE DETECTION OF GROUP B STREPTOCOCCI IN PREGNANT WOMEN (1, 2, 3, 4). THIS BROTH CAN ALSO BE USED FOR THE ENRICHMENT OF S. AUREUS WITHIN THE SCOPE OF METHICILLIN-RESISTANT S. AUREUS DETECTION. ISSUE DESCRIPTION: A CUSTOMER IN ITALY NOTIFIED BIOMÉRIEUX OF NO GROWTH IN ASSOCIATION WITH TODD HEWITT BROTH + ATB 20T 9ML (REF. (B)(4), LOT. 1009554700, EXP. DATE: 6/20/2023). THE CUSTOMER REPORTED AN ANOMALY IN THE GROWTH OF STREPTOCOCCUS AGALACTIAE AFTER ENRICHMENT IN BROTH WITH (B)(6) ((B)(6)) . IN PARTICULAR, THE CUSTOMER OBSERVED A MASSIVE GROWTH IN GBS AND CNA FROM DIRECT SEEDING OF THE VAGINAL SWAB BEFORE THE BROTH ENRICHMENT PROCEDURE AND THE ABSENCE OF GROWTH OF THE SAME STREPTOCOCCUS AGALACTIAE FROM SEEDING ON GBS AND CNA AFTER BROTH ENRICHMENT. THE LABORATORY PROCEDURE FORESEES BOTH THE DIRECT SEEDING OF VAGINAL AND RECTAL SWABS ON CNA AND GBS AND THE ENRICHMENT IN BROTH, FOLLOWED BY INCUBATION IN A THERMOSTAT FOR 18-24H AND THE SUBSEQUENT SEEDING FROM BROTH AGAIN ON CNA AND GBS. STREPTOCOCCUS AGALACTIAE IDENTIFICATION WAS CONFIRMED WITH VITEK 2 CARD. THE CUSTOMER WAS ABLE TO REPORT BUT THERE WAS DI

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16673459 ↗

Other CULTURE MEDIA, SELECTIVE BROTH devices

All CULTURE MEDIA, SELECTIVE BROTH devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page