ECHELON 71340412Recalls & reported problems
Smith & Nephew, Inc. · ECHELON 260MM POROUS BOWED FEMORAL COMPONENT STANDARD COLLAR SIZE 12 LEFT · Class 2 · Implant
All models of ECHELON (30)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010383945), received between Feb 9, 2022 and Feb 9, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Material Twisted/Bent” (1 report).
1 other recall cover devices cleared under the same FDA submission (K211176, K983834); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Twisted/Bent1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 9, 2022Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT, AFTER A PRIMARY LEFT TOTAL HIP ARTHROPLASTY HAD BEEN PERFORMED, THE PATIENT FELL DOWN AND EXPERIENCED A VANCOUVER TYPE B3 PERIPROSTHETIC FRACTURE. THEREFORE, A REVISION SURGERY WAS PERFORMED IN ORDER TO SOLVE THIS ADVERSE EVENT, AND IT WAS FOUND THAT THE ACETABULAR COMPONENT WAS STABLE, BUT THE FEMORAL COMPONENT WAS REVISED WITH AN ECHELON 260MM POROUS BOWED FEMORAL COMPONENT STANDARD COLLAR SIZE 12 LEFT. ON SIXTH WEEK CONTROL, IT WAS FOUND ON X-RAYS THAT THE ECHELON 260MM POROUS BOWED FEMORAL STEM IS BENDING. IT IS UNKNOWN IF ANY INTERVENTION HAS BEEN PERFORMED. IT IS UNKNOWN IF A SECOND REVISION SURGERY HAS BEEN SCHEDULED. THE CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.
Patient problems: Failure of Implant
MAUDE report 13499022 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K211176, K983834. One submission often covers many models, so check the product and lot details in each record.
- Z-0326-2025 · Oct 15, 2024 · Open, ClassifiedTandem Intl Bipolar Cocr Shell/UHMWPE Liner, TI-6AL-4V Retaining Ring, 28MM I.D. 46 MM O.D., REF 71324046, sterile, femoral head bipolar component of the Tandem Bipolar Hip System.
Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices
- NA 1365-51-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented753 reports
- NA 1365-50-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented412 reports
- ARTICUL/EZE 1365-21-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 recall280 reports
- ARTICUL/EZE 1365-11-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 death262 reports
- LFIT 6260-9-236Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, cemented256 reports
- PINNACLE GRIPTION 1217-32-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented2 deaths239 reports
- ELEOS™ 25002111EOnkos Surgical, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented3 deaths230 reports
- Novation 130-36-52Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented2 recalls124 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page